Elba N55 340 Série Mode D'emploi page 20

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

VENTILATION REQUIREMENTS (models with gas burners)
The appliance must be installed in compliance with applicable local regulations con-
cerning ventilation and the evacuation of exhaust gases.
Intensive and prolonged use may require extra ventilation, e.g. opening a window, or
more efficient ventilation increasing the mechanical suction power if this is fitted.
CHOOSING SUITABLE SURROUNDINGS
The room where the gas appliance is to be installed must have a natural flow of air so that
the gas can burn (in compliance with applicable local regulations).
The flow of air must come directly from one or more openings made in the outside walls
with a free area of at least 100 cm
If the appliance does not have a no-flame safety device this opening must have an
area of at least 200 cm
The openings should be near the floor and preferably on the side opposite the exhaust for
combustion products and must be so made that they cannot be blocked from either the
outside or the outside.
When these openings cannot be made, the necessary air can come from an adjacent room
which is ventilated as required, as long as it is not a bed room or a danger area (in com-
pliance with applicable local regulations).
In this case, the kitchen door must allow the passage of the air.
DISCHARGING PRODUCTS OF COMBUSTION
Extractor hoods connected directly to the outside must be provided, to allow the products
of combustion of the gas appliance to be discharged (Fig. 6.3).
If this is not possible, an electric fan may be used, attached to the external wall or the win-
dow; the fan should have a capacity to circulate air at an hourly rate of 3-5 times the total
volume of the kitchen (Fig. 6.4).
The fan can only be installed if the room has suitable vents to allow air to enter, as descri-
bed under the heading "Choosing suitable surroundings".
Extractor hood
for products of
combustion
Air vent
Fig. 6.3
20
(or refer to applicable local regulations).
2
(or refer to applicable local regulations).
2
Electric fan to
extract products
of combustion
Air vent
Fig. 6.4

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

N55 342 sérieN55 440 sérieN55 442 sérieN55 042 série

Table des Matières