Transport And Storage; Transport; Storage; Installation/Assembly And Connection - LUTZ B2 Vario PP 32-SL Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

en

4. Transport and storage

4.1 Transport

Unpacking and check of condition on delivery
► Unpack the pump on receipt and check for
transport damages.
► Report transport damage to the manufacturer
immediately.
► Check that the consignment is complete as
ordered.
The following is included in scope of supply of the
pump with 9ft. cord and plug (→ Fig. 2):
Pump
Lutz B2 Vario
1 Hose connector
for 3/4" hose
1 Wing nut
Tab. 5: Scope of supply

4.2 Storage

WARNING
!
Danger of injury and intoxication when
handling hazardous liquids!
► Always wear protective equipment when
working on the pump.
NOTICE
Damage of property as a result of incorrect
storage!
► Complete emptying of pump tube.
► Store the pump at a protected and easy accessi-
ble place in an upright position.
► Prevent residual liquid from dripping onto the
floor, when hanging up the pump.
► Store pump dry, protected against weather
effects and UV-rays.
8
Pump set
Item
Lutz B2 Vario
No:
1 Hose connector
for 3/4" hose
1 Wing nut
Á
1 Wall bracket
Â
5 ft. PVC hose
Ã
1 Lutz nozzle, PP
Ä
2 Hose clips 3/4"
Å
5. Installation/Assembly and
connection
► Fix the wall bracket (pump set Lutz B2 Vario) on
a sheltered, easily accessible place (→ Fig. 3).

5.1 Fixing of the pump tube

!
CAUTION
Danger of injury due to tipping over of empty
drums and containers!
► The pump tube must always be positioned
vertically in the bunghole.
► If necessary, use a drum adapter or emission
control drum adapter.

5.2 Safe use

!
DANGER
Danger of death by electric shock or explosion!
► Do not immerse the pump deeper than the
outrun piece (→ Fig. 1A).
► The pump must not be used to pump flammable
liquids (→ Fig. 1B).
► Do not subject the outrun piece to tension or
pressure (→ Fig. 4).
► The bending moment M
exceed the following values:
Pump material
Polypropylene (PP)
Polyvinylidene fluoride
(PVDF)
Stainless steel
(SS 1.4571)
Tab. 6: Maximum permissible bending moment M
at the outlet must not
B
Maximum bending
moment M
B
88 in-lbs / 10 Nm
88 in-lbs / 10 Nm
265 in-lbs / 30 Nm
B

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

B2 vario pvdf 32-slB2 vario ss 28-sl

Table des Matières