MICROSWITCHES S1-1, S1-2, S1-3, S1-4 AND S1-5
The values of the microswitches S1-1, S1-2, S1-3, S1-4 and S1-
5 define the call address of the bracket in question with respect
to the external call unit.
To use the two-residence intercom call function, the users
(telephones and/or video entry phones) must be set to contiguous
call addresses marked with the same letter (AA...CC....YY) in the
table on page 35.
Operation
• By pressing the call button, the visitor activates the white LEDs
for illuminating the person, the internal call ringtone (if the
Privacy function is not enabled) and displays the image on the
main monitor/s for approx. 60 seconds.
On answering the communication, the maximum duration of the
conversation is 90 seconds.
A call confirmation tone sounds at the external unit; in systems
with 2 or more entrances, if the external unit emits an engaged
tone instead of the ringtone this means that another
communication is already in progress with another external unit.
In case of a persistent short-circuit on the bus line, the
external unit emits an intermittent signalling tone.
• Communication occurs at the internal unit by lifting the handset.
• The brightness control and ringtone volume control are located
on the left-hand side of the monitor.
• The button marked with the key symbol acts on the electric lock,
activating it for about 2 sec.
• Automatic switch-on of the main monitor occurs by pressing
Pushbutton 2 with function enabled (see description on page 39).
In systems with 2 external units, it is possible to view the image
from one external unit or the other alternately ("toggle" function)
by pressing Pushbutton 2.
Automatic monitor switch-on is not possible during another
conversation.
• For the intercom functions of the DIVA KIT System, refer to
page 36.
• For programming user addresses different from the factory
settings (1 and 2) refer to page 35.
Main or secondary additional monitors
The setting of JP1 defines whether the bracket in question will be
managed as main or secondary. The external unit can manage up
to a maximum of 3 video entry phones or telephones for each Call
button. When a call is made from the external unit, the monitor
switched on by the system will be that of the main video entry
phone.
Any other secondary monitors in the same residence unit will remain
off. By answering the external unit call from a secondary video entry
phone, the image is automatically displayed on the monitor.
The monitor of the main video entry phone will be switched off and
the image will be displayed on the monitor of the video entry phone
on which Pushbutton 2 - video request was pressed.
The image transmitted from the external unit can be viewed even
without lifting the handset, simply by pressing Pushbutton 2 -
video request.
In the classic DIVA KIT configuration, it is therefore possible to
have at most 2 secondary video entry phones and 1 main video
entry phone for each Call button, all powered by the same Art.
1205/B (Variant KD/CC page 79).
It is possible to manage up to 3 main video entry phones within the
same residence unit (i.e. set to the same user code). In this
particular configuration, the additional main video entry phones
must each be powered by the special Art. 1212/B (Variant KD/HC
and KD/IC page 78, 79).
At the call from the external unit, the image will be displayed on
each of the main video entry phones connected to the system.
In any case, even when using Art. 1212/B, a max. of 3 video entry
phones can be connected for the same residence unit. A dedicated
power supply is not necessary for any optional telephone.
S1-6, S1-7, S1-8
Setting DIVA KIT operating mode
The table on page 36 shows the functions of the single monitor
pushbuttons according to how the microswitches S1-6, S1-7, S1-8
are set.
Description of pushbutton functions

Door lock release

pushbutton activates the lock connected to the external unit.
Actuator
Pressing the pushbutton set in Actuator mode
enables activation of Art. 1256, which can be used to open
gates, up&over doors, etc., or to activate the cyclic camera
module Art. 1259C.
Free Pushbutton
The indication Free Pushbutton means that
the pushbutton can be used as a C.NO. contact in the terminal
block, by means of suitable settings as illustrated in the KD/PC
variant on page 85.
Video request / Automatic Switch-on
this mode to display the image on the monitor transmitted by the
external unit, even if no call has been made.
For use and activation of the service, see variant KD/PC on
page 85. In systems with two external units, it is possible to view
the image from one external unit or the other alternately ("swing"
function) by pressing the pushbutton again.
On secondary monitors, Pushbutton 2 also has the video request
function (for more information see page 39).
Switchboard call
Press the pushbutton set in this mode to
send a call to the system porter Switchboard.
Single-residence intercom call
this mode to send a call to the other units (video entry phones
and/or telephones) set to the same call address.
By lifting the handset, the receiver of the call communicates with
the caller.
MT KIT
Pressing the Door lock release
Press Pushbutton 2 in
Press the pushbutton set in
37
MT KIT

Publicité