GROUP S.P.A.
Schema di connessione a porta principale con centralino Art. 1998A (opzionale) di 30 DIVA KIT (massimo). Derivazione Diva Kit da 1214KC.
IT
Wiring diagram of a main door connection with porter switchboard Art. 1998A (optional) with 30 DIVA KITS (maximum). Diva Kit branch from 1214KC.
EN
Schema de connexion a la plaque de rue principale avec standard Art. 1998A (en option) de 30 DIVA KIT (maximum). Dérivation Diva Kit de 1214KC.
FR
N.B. Le impostazioni di S1-6, S1-7 e S1-8 sono in funzione della configurazione desiderata (vedi tabella a pag 14).
NOTE: The S1-6, S1-7 and S1-8 settings depend on the configuration required (see table on page 38).
NOTE: Les programmations de S1-6, S1-7 et S1-8 sont en fonction de la configuration désirée (voir tableau page 62).
L'Art. 1236 va utilizzato in impianti cablati in questa
configurazione con più di 16 kit (Art. 8491 e Art. 8492)
derivati. L'Art. 1236 va posto in prossimità dell'uscita
Lout-Lout del morsetto Art. 1214KC relativo al kit posto
a metà impianto.
Esempio:
- in impianti con 18 derivati posizionare l'Art. 1236
dopo il nono morsetto Art. 1214KC.
- in impianti con 23 derivati posizionare l'Art. 1236
dopo il dodicesimo morsetto Art. 1214KC.
- in impianti con 30 derivati posizionare l'Art. 1236
dopo il quindicesimo morsetto Art. 1214KC.
Per maggiori informazioni sull'utilizzo dell'Art. 1236
consultare la documentazione tecnica allegata al prodotto.
Per maggiori informazioni sulla distanza massima tra
Art. 1214KC e il monitor più lontano vedi la tabella
riportata a pagina 10. Per maggiori informazioni in
merito alle impostazioni necessarie per l'Art. 1224A
fare riferimento al manuale tecnico MT/SBC/01.
MT KIT
88
KD/EN/101C
Art. 1236 must be used in systems cabled in this
configuration with more than 16 kits (Art. 8491 and Art.
8492) branched off. Art. 1236 must be placed near the
Lout-Lout output of terminal Art. 1214KC relative to the
kit placed half-way through the system.
Example:
- in systems with 18 branches, position Art. 1236 after
the ninth terminal Art. 1214KC.
- in systems with 23 branches, position Art. 1236 after
the tenth terminal Art. 1214KC.
- in systems with 30 branches, position Art. 1236 after
the fifteenth terminal Art. 1214KC.
For further information on the use of Art. 1236, consult
the technical documentation enclosed with the product.
For further information on the maximum distance
between Art. 1214KC and the monitor furthest away,
see the table given on page 34. For further information
regarding the settings required for Art. 1224A, refer to
the MT/SBC/01 technical manual.
L'Art. 1236 s'utilise dans des installations câblées
ayant cette configuration avec plus de 16 kits (Art.
8491 et Art. 8492) dérivés. Placer l'Art. 1236 à
proximité de la sortie Lout-Lout de la borne Art.
1214KC relative au kit placé au milieu de l‚installation.
Par exemple:
- dans des installations avec 18 dérivés, placer l'Art.
1236 après la neuvième borne Art. 1214KC.
- dans des installations avec 23 dérivés, placer l'Art.
1236 après la douzième borne Art. 1214KC.
- dans des installations avec 30 dérivés, placer l'Art.
1236 après la quinzième borne Art. 1214KC.
Pour plus de détails sur l'utilisation de l'Art. 1236, voir
la documentation technique annexée au produit.
Pour plus de détails sur la distance maximum entre
l'Art. 1214KC et le moniteur le plus éloigné, voir le
tableau illustré à la page 58. Pour plus de détails sur
les réglages nécessaires pour l'Art. 1224A, faire
référence au manuel technique MT/SBC/01.