Description Of Diva Kit Connection Diagrams; Kd/01/Ac Diagram For Single-Residence Kit With Additional Power Supply Art. 1395; Connection In Cascade; Branch Connection - Comelit COLOR DIVA MT KIT 11 Manuel Technique

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

GROUP S.P.A.

DESCRIPTION OF DIVA KIT CONNECTION DIAGRAMS

Main diagram for single-residence kits Art. 8491
Diagram KD/01C
Main diagram for single-residence kits Art. 8491
Refer to the indications given on page 32 for the wires to be used and
the maximum operation distances.
Configuration of microswitches (hereinafter DIP) on the bracket:
DIP 1 ON - DIP 2, DIP 3, DIP 4, DIP 5 OFF:
set user code number 1 for call from single-residence external unit
(4875KC).
DIP 6, DIP 7, DIP 8: depending on the required functions.
JP1 in position P: sets the monitor bracket as main.
Refer to the table on page 35 for indications regarding settings of
possible configurations.
Main diagram for two-residence kits Art. 8492
Diagram KD/02BC

Branch connection

Main diagram for two-residence kits Art. 8492.
Refer to the indications given on page 32 for the wires to be used and
the maximum operation distances.
Configuration of microswitches (hereinafter DIP) on the bracket:
DIP 1 ON - DIP 2, DIP 3, DIP 4, DIP 5 OFF:
set user code number 1 for call from two-residence external unit
(4876KC).
DIP 2 ON - DIP 1, DIP 3, DIP 4, DIP 5 OFF:
set user code number 2 for call from two-residence external unit
(4876KC).
DIP 6, DIP 7, DIP 8: depending on the required functions.
JP1 in position P: sets the monitor bracket as main.
Refer to the table on page 35 for indications regarding settings of
possible configurations. End the riser with terminal Art. 1216 as
shown in the diagram.
The max. distance between Art. 1214KC and the monitor is 20 m.
Diagram KD/02AC

Connection in cascade

Main diagram for two-residence kits Art. 8492.
Refer to the indications given on page 32 for the wires to be used and
the maximum operation distances.
Configuration of microswitches (hereinafter DIP) on the bracket:
DIP 1 ON - DIP 2, DIP 3, DIP 4, DIP 5 OFF:
set user code number 1 for call from two-residence external unit
(4876KC).
DIP 2 ON - DIP 1, DIP 3, DIP 4, DIP 5 OFF:
set user code number 2 for call from two-residence external unit
(4876KC).
DIP 6, DIP 7, DIP 8: depending on the required functions.
JP1 in position P: sets the monitor bracket as main.
Refer to the table on page 35 for indications regarding settings of
possible configurations. End the riser with terminal Art. 1216 as
shown in the diagram.
Diagram for two-residence kits Art. 8492 extended
with a second 4876KC
Diagram KD/03BC
Branch connection
Main diagram for two-residence kits Art. 8492.
Refer to the indications given on page 32 for the wires to be used and
42
MT KIT
the maximum operation distances.
Configuration of microswitches (hereinafter DIP) on the bracket:
DIP 1 ON - DIP 2, DIP 3, DIP 4, DIP 5 OFF:
set user code number 1 for call from two-residence external unit
Page 69
(4876KC).
DIP 2 ON - DIP 1, DIP 3, DIP 4, DIP 5 OFF:
set user code number 2 for call from two-residence external unit
(4876KC).
DIP 6, DIP 7, DIP 8: depending on the required functions.
JP1 in position P: sets the monitor bracket as main.
Refer to the table on the previous pages for indications regarding set-
tings of possible configurations. By purchasing a switching device Art.
1224A and a second external unit Art. 4876KC the two-residence
system can be extended with two external units.
The same operation is possible with the single-residence kits.
In systems equipped with 2 Art. 4876KC, it is possible to view the
image from one external unit or the other alternately ("toggle" func-
tion) by pressing the automatic switch-on pushbutton. End the riser
Page 70
with terminal Art. 1216 as shown in the diagram.
The max. distance between Art. 1214KC and the monitor is 20 m.
Diagram KD/03AC
Connection in cascade
Main diagram for two-residence kits Art. 8492.
Refer to the indications given on page 32 for the wires to be used and
the maximum operation distances.
Configuration of microswitches (hereinafter DIP) on the bracket:
DIP 1 ON - DIP 2, DIP 3, DIP 4, DIP 5 OFF:
set user code number 1 for call from two-residence external unit
(4876KC).
DIP 2 ON - DIP 1, DIP 3, DIP 4, DIP 5 OFF:
set user code number 2 for call from two-residence external unit
(4876KC).
DIP 6, DIP 7, DIP 8: depending on the required functions.
JP1 in position P: sets the monitor bracket as main.
Refer to the table on the previous pages for indications regarding
settings of possible configurations. By purchasing a switching devi-
Page 71
ce Art. 1224A and a second external unit Art. 4876KC the two-resi-
dence system can be extended with two external units. The same
operation is possible with the single-residence kit. In systems equip-
ped with 2 Art. 4876KC, it is possible to view the image from one
external unit or the other alternately ("toggle" function) by pressing
video request Pushbutton 2. End the riser with terminal Art. 1216 as
shown in the diagram.
Diagram for two-residence kits extended with a
second Art. 4876KC, an additional secondary monitor
and an telephone for each residence unit.
Diagram KD/04BC
Branch connection
Diagram for two-residence kits extended with a
second Art. 4876KC, an additional main monitor and
an telephone for each residence unit.
Diagram KD/04AC
Connection in cascade
Page 72
Diagram for single-residence kit with additional power
supply Art. 1395
Diagram KD/01/AC
Page 73
Page 74
Page 75
Page 76

Publicité

Chapitres

Table des Matières
loading

Table des Matières