Style door-entry phone Art. 2608
Basic door-entry phone with 2 buttons as standard.
Cannot be used for the intercom function.
The door-entry phone must always be mounted using Art. 1214/2C,
as illustrated in the PXK/DC wiring diagram on Page 73.
1 Lock-release button A .
2 Button P1 for Switchboard call / Generic actuator / button for
various uses present on terminal block (P1 C1).
3 3-position ringtone/Privacy service selector:
High position: Maximum ringtone volume.
Middle position: Medium ringtone volume.
Low position: Privacy service activation
(Privacy service means exclusion of the call ringtone from the
external unit and switchboard; activation of this function is
signalled by a red indicator appearing in the top right-hand
corner).
4 Privacy function indicator.
5 System connection terminals:
L L Bus line connection.
CFP CFP Floor door call input.
P1 C1 Terminals for button P1 C. NO. 24V 100mA dedicated to
various services (remove CV1 and CV2).
S+ S- Terminals for call repetition device.
6 JP1 Jumper for selecting Switchboard call (position C)/Generic
actuator (position A) function of button P1 (see adjacent figure).
7 CV1 CV2 Jumper to be removed in order to have potential-
free contact C. NO. contact on button P1.
8 Dip switch for setting user code (see table on Page 31).
9 Trimmer for adjusting the microphone volume.
Clean using a damp cloth. Do not use alcohol or other
aggressive products.
+
-
C
M I
MT KIT 14
27
MT KIT 14