TECHNICAL DATA

5.1 Operating Conditions
WARNING!
Risk of injury.
Malfunction if used outside.
▶ Do not use Type 0127 outside and avoid heat sources which may
cause the permitted temperature range to be exceeded.
Ambient temperature
Medium temperature
Nominal width
Seal material
DN 0,8
FFKM
DN 0,8
FKM
DN 0,8
EPDM
DN 1,2 und 1,6
FFKM
DN 1,2 und 1,6
FKM
DN 1,2 und 1,6
EPDM
5.5 Pneumatic Data
Operating principles
A
2/2-way valve, direct action, closed with no
A
current
P/NC
B
2/2-way valve, direct action, opened with no
B
current
P/NO
A in/out
3/2-way valve, direct-acting,
T
all-purpose
P/NC R/NO
Pressure range
see type label
Line connections
Threaded connection G1/8,
NPT1/8 or UNF1/4-28
Flanged connection
Hose connection
Note the information specified on the rating plate for voltage,
type of current, and pressure.
6
5.6 Electrical Data
Operating voltage
12 V DC
24 V DC
24 V UC
Voltage tolerance
± 10 %
Nominal power
12-24 V
3.0 W
Nominal operating mode Long-term operation,
duty cycle 100 %
for block assembly
if temperatures of media or
surrounding area above +40 °C:
intermittent duty 40% (10 min)
Note the information specified on the rating plate for voltage,
type of current, and pressure.
0 ... +55 °C
Temperature range
+5...+50 °C
0...+50 °C
-5...+50 °C
+10...+50 °C
+5...+50 °C
-5...+50 °C
english
Media
neutral and aggressive liquids and
gases which do not corrode the
housings and seal materials (see resistance table at
www.burkert.com → Type)
Protection class IP54 with wires and individual device socket
IP20 with multi-device socket
5.2 Conformity
The solenoid valve Type 0127 conforms to the EC directives according
to the EC Declaration of Conformity (if applicable).
5.3 Standards
The applied standards, which are used to demonstrate compliance with
the EC Directives, are listed in the EC type test certificate and/or the EC
Declaration of Conformity (if applicable).
5.4 Mechanical Data
Dimensions
see data sheet
Housing material
PVDF, ETFE, PEEK,PPS
Sealing material
FFKM, FKM, EPDM
english
5.5.1 Rating plate (example)
Nominal width
Operating principle
Type
S/N
00073606
Ident. no.
if applicable
Voltage/frequency output
Nominal connection pressure
6
INSTALLATION
6.1 Safety Instructions
WARNING!
Risk of injury when installing the valve.
▶ This work may be carried out by authorised technicians only and with
the appropriate tools.
▶ After an interruption in the power supply or pneumatic supply, ensure
that the process is restarted in a defined or controlled manner.
6.2 Fluid Installation
DANGER!
Danger – high pressure.
Danger of severe injuries from reaching into the system.
▶ Before loosening the lines and valves, turn off the pressure and vent
the lines.
Installation position:
any position, preferably with the drive facing up.
english
Type 0127
Housing materia
Seal material
0127
T
1,6 FFKM PD
PN0-2
bar / 29 PSI
24V
AC/DC
3W
1940
W13ME
5
7