Viking GE 150 Manuel D'utilisation page 49

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 51
GE 150.1/GE 250.1/GE 250.1 S:
Power
2500 W
GB
2500 W
CH
2000 W
Amperage rating
11.4 A
GB
12.0 A
CH
9.3 A
Rated voltage
230 V~
Speed
2800 rpm
1
Fuses
16 A
10 A (CH)
Frequency
50 Hz
Protection class
I
Type of protection
Splash proof
(IP X4)
Operating conditions
S6/40%
4 min
Load time 6 min
Idle time
GE 150.1:
In accordance with
Directive
2000/14/EC:
Guaranteed sound
power level L
99 dB(A)
WAd
In accordance with
Directive
2006/42/EC:
Sound pressure level
at workplace L
89 dB(A)
pA
Uncertainty K
2 dB(A)
pA
Bolt tightening torques:
Blade disc
50 Nm
Reversible blade
10 Nm
Weight
26 kg
27 kg (GB)
L/W/H
95/48/114 cm
0478 201 9906 D - EN
GE 250.1/GE 250.1 S:
In accordance with
Directive
2000/14/EC:
Guaranteed sound
power level L
103/100 dB(A)
WAd
In accordance with
Directive
2006/42/EC:
Sound pressure level
at workplace L
92/90 dB(A)
pA
Uncertainty K
3 dB(A)
pA
Bolt tightening torques:
Blade disc
50 Nm
Reversible blade
10 Nm
2
Shredding blades
10 Nm
Weight
28/27 kg
29/28 kg (GB)
27 kg (CH)
L/W/H
107/48/143 cm
GE 260.1/GE 260.1 S:
Motor, type
BSRF 0.75/2-C
Power
2900 W
Amperage rating
4.8 A
Rated voltage
400 (3~) V~
Speed
2780 rpm
Fuses
10 A
Frequency
50 Hz
Protection class
I
Type of protection
Splash proof
(IP X4)
Operating conditions
S6/40%
4 min
Load time 6 min
Idle time
GE 260.1/GE 260.1 S:
In accordance with
Directive
2000/14/EC:
Guaranteed sound
power level L
102/101 dB(A)
WAd
In accordance with
Directive
2006/42/EC:
Sound pressure level
at workplace L
89/91 dB(A)
pA
Uncertainty K
3 dB(A)
pA
Bolt tightening torques:
Blade disc
50 Nm
Reversible blade
10 Nm
2
Shredding blades
10 Nm
Weight
28/27 kg
L/W/H
107/48/143 cm
1)
Caution:
In the case of mains fuses of less
than 16 A, these may be tripped dur-
ing start-up or in the case of high
load operation of the machine.
2)
for models GE 250.1 and GE 260.1
19. Troubleshooting
If necessary, contact a specialist
dealer; VIKING recommends VIKING
specialist dealers.
Fault:
Motor does not start
Possible cause:
– Motor overload protection activated
– No mains voltage
– Electric cable, plug, plug connector or
switch defective
47

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ge 250Ge 250 sGe 260Ge 260 s

Table des Matières