Hofmann geodyna 4500-2 Mode D'emploi page 93

Table des Matières

Publicité

Error codes
E83 – Fig. 91
During a measuring run the measured data have been
made useless under the effect of outside pulses (e. g.
vibrations) and measurement was interrupted.
Repeat the measuring run.
E88 – Fig. 92
The rotating speed of the main shaft exceeds the
safety limit.
E89 – Fig. 93
A key is jammed at power–on.
Find and release the jammed key, call service if
necessary.
E92 – Fig. 94
Distance gauge arm defective.
Call service.
As long as the gauge arm is defective, enter distance
and nominal rim dimensions by pressing the function
keys and rotating the wheel (see § 8.3).
Operation manual
geodyna 4500-2/p – ZEEWB727B03
Codes d'erreur
E83 –
Fig.
91
Pendant une lancée de mesure, les données mesurées
sont devenues inutilisables par suite des impulsions
extérieures (p. ex. vibrations) et la mesure a été
interrompue.
Répéter la lancée de mesure.
E88 – Fig. 92
La vitesse de l'arbre principal dépasse la plage de
sécurité.
E89 – Fig. 93
Une touche s'est coincée avant de la mise en circuit.
Chercher la touche et la débloquer ; le cas échéant,
appeler le service.
E92 – Fig. 94
La pige de mesure est défectueuse.
Faire appel au service après-vente.
Entretemps, entrer l'écart et les dimensions nominales
de jante au moyen de la touche de fonction
correspondante et en tournant la roue (voir § 8.3).
Mode d'emploi
geodyna 4500-2/p – ZEEWB727B03
89

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Geodyna 4500-2p

Table des Matières