MS660
Function 20 (Deactivation of faulty door contacts)
On vehicles without an interior light delay, this function must remain programmed to
"Off" (factory setting).
On vehicles with interior light delay, this function can be programmed to "On" so
that it detects doors left open by accident. As a result, the door can still be closed for
the first 15 sec. after activation of the alarm system to keep it in the alarm circuit. If the
door is closed after the 15 sec., it will no longer be monitored.
Function 24 (Visual signals)
A connection to the indicator cables has been provided at the factory. In the event of
an alarm, both alarm system indicator outputs generate a +12 volt interval signal.
If you wish to connect the optical signals via the hazard lights switch, you must
program this to "Hazard lights". In this case, a short earth signal is switched from
both alarm system indicator outputs. After the alarm has finished (30 sec.), a further
earth signal is switched to deactivate the hazard light system.
10.3
Programming
Starting the programming mode
➤ Deactivate the alarm system using the remote control: Press the "Unlock" button.
➤ Open the driver's door and switch on the ignition.
➤ Press and hold the "Unlock" button and switch the ignition off.
➤ Release the "Unlock" button.
✓ The status LED lights up. You have now accessed the program menu.
I
NOTE
If 30 sec. elapse without a button being pressed, the program menu will
be quit automatically.
EN
Programming MagicSafe