Connecting the power to MagicSafe
Connecting siren MS-620SI (accessory part)
➤ Connect the yellow cable and the green/yellow cable to siren MS-620SI in
accordance with fig. b, page 8.
➤ Program software function 13 to "Alarm output".
➤ Program software function 9 to "Siren".
Connecting the vehicle horn
➤ Connect the yellow cable and the green/yellow cable to the vehicle horn in
accordance with fig. c, page 8.
➤ Program software function 13 to "Alarm output".
➤ Program software function 9 to "Horn".
A
NOTICE!
When connecting the vehicle horn, an operating current relay with a
recovery diode must be used which has a rating of at least 20 A.
Free slot (P6)
Not assigned.
Orange (P7)
➤ Connect this cable to a connection which is switched by the ignition
(terminal 15).
Grey (P8)
➤ Connect this cable to the bonnet contact switch (fig. a 8, page 7).
The factory setting allows for a switch which is closed when the bonnet is open.
In case an original switch is to be used which is open when the bonnet is open,
this can be programmed in the control unit, see chapter "Function 15 (Bonnet
contact input)" on page 40.
Blue (P9)
This is the signal cable for the ultrasonic module. It ends in the 3-pole compact plug
(fig. a 15, page 7).
Green (P10)
See P5.
28
MS660
EN