Connecting the power to MagicSafe
No.
Designation
15
3-pin plug for connection to the ultrasonic module
16
Ultrasonic sensors
17
Red plug connection ultrasonic sensor – ultrasonic module
18
Ultrasonic module
19
White plug connection ultrasonic sensor – ultrasonic module
20
Simultaneous connection to door contact switch and to the boot contact switch
(with inverse diodes only!)
21
Connection to door contact switches only (without inverse diodes!)
22
Red plug connection for key holder
23
White plug connection for key holder
24
Key holder incl. status LED
All plugs are coded so that you cannot connect them incorrectly.
8.1
Laying cables
When laying the cables, make sure:
• they are not kinked or twisted
• they do not rub on edges
• they are not laid in sharp-edged ducts without protection (fig. 3, page 4).
A
NOTICE!
Before drilling any holes, make sure that no electrical cables or other
parts of the vehicle can be damaged by drilling, sawing and filing
(fig. 2, page 4).
➤ When laying cables in the engine compartment or boot, use existing openings
with rubber seals wherever possible.
Where there is no suitable opening, drill a hole with a diameter of
approximately 13 mm, and insert a cable duct sleeve.
I
NOTE
Pull the socket connectors of the cables through the cable duct sleeve
before inserting the sleeve in the bodywork.
26
MS660
EN