Testing other alarm inputs
➤ Test the function of the other alarm inputs in order by triggering an alarm.
➤ Count the number of flashes on the status LED afterwards.
If the number of flashes does not correspond to the specified value, you need to
check the connections and cables.
Number of flashes
0 (status LED off)
1
2
3
4
5
7
8
9
9.5
Testing optical and acoustic signals
➤ Trigger an alarm.
During the alarm, all indicators must be switched on and the vehicle horn or alarm
siren, as well as the status LED, must signal the alarm.
EN
Alarm cause
No alarm triggered
Voltage drop sensor
Ultrasonic sensors (interior)
Door/boot contact switch
Bonnet contact switch
Ignition
Additional alarm input
Radio sensor
The battery in the hand-held transmitter is too weak