3.3. Specific operation
Depending on the installed additional devices, the drive may operate in the
following specific ways:
3.3.1. Operation with safety cells
Gate open: an obstacle placed between the cells will inhibit closing of the
gate as the cells have detected a presence.
Gate moving: If an obstacle is detected while the gate is opening, the
gate will continue moving (cell status not recognised).
If an obstacle is detected when closing, the gate will stop for
1 second and then reopen automatically.
3.3.2. Operation with orange flashing light
The orange light is activated during any movement of the gate with a
2-second warning.
3.3.3. Operation with zonal lighting
Zonal lighting comes on with the motor, and goes out 1 minute and 30
seconds a er the motor has come to a complete stop.
3.3.4. Operation using the backup battery
If a backup battery is installed, the drive will work even during a power
outage.
Operation is then activated under the following conditions:
• The gate leaves open one a er the other at reduced speed.
• The additional devices (photoelectric cells, orange light, wired code
keypad, etc.) do not operate.
Battery specifications:
• Operating range: 24 hrs; 10 operating cycles depending on the
weight of the gate.
• Recharging time: 48 hours
• Service life before replacement: Approximately 3 years.
For optimum battery life it is recommended that the main power supply be
switched off and the motor operated using the battery for several cycles,
three times a year.
3.4. Manual back release
In case of a power cut, the manual back release device makes it possible
to open the gate.
Unlock the motor arms by turning the button located above the motors.
Padlock closed: arm locked; padlock open: arm unlocked, manual op-
eration.
Attention
In the unlocked position, move the arms slowly to avoid damaging
the motors.
4
4. MAINTENANCE
4.1. Checks
4.1.1. Safety devices (cells)
Check for correct operation every 6 months (see page 4).
4.1.2. Backup battery
For optimum battery life, it is recommended that the main power supply be
switched off and the motor operated using the battery for several cycles,
three times a year. Contact a qualified person (installer) to have the backup
battery replaced.

4.2. Replacing the battery

4.2.1. Keytis RTS
4.2.2. Keygo RTS
Axovia 220B RTS