Operation
EN
8- Program Memory
TIG Mode;
• With its 100 program memory feature, it can save your parameter settings. You can recall them as required by your work type. By this
means, each time you change the work, you will not have to set parameters; the production standard will be preserved. Whichever
memory (job) number is selected, all settings will automatically be saved in that number.
• Change the program number for different parameter entries.
• The display above the program button shows which parameter you have changed in the program.
• There are 100 programs available between 0-99.
• You can switch to the other program by pressing the program button once, if you press and hold, you can switch between the programs
quickly.
MMA Mode;
• (U) When you want to see the welding output voltage, you can see the voltage unit by pressing the button once. You can switch to
the ampere unit by re-pressing the button and display the current value (A) on the digital display.
9- Digital Display
The set welding current, parameter values and error codes can be monitored visually on the digital display.
10- Low / High Voltage Protection
• Protects your machine against physical faults by means of a special circuit in faulty mains voltages.
• Mains voltage control available.
• If the mains voltage is above 250 V or below 185 V, the system issues an error code as inappropriate mains and a warning LED is
displayed.
11- Thermal Protection
• Double protection to prevent overheating and damage of your machine. The intelligent processor digitally performs temperature control
whereas a second protection for the machine will be performed manually.
• Thermic control available.
• If the Igbt block rises above 80 degrees, the red LED lights and the error code will be displayed. Gives a thermic error.
USER MANUAL | MANUEL D'UTILISATION | РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ | KULLANIM KILAVUZU
• By this function, the breakage of the oxide layer and the smoothness of the welding seam after breakage will be
finely adjusted according to the material thickness and tungsten diameter.
• The default factory setting is 35%.
• Will be replaced depending on the workpiece thickness and user request.
Example;
Let AC balance be set to 35% welding and penetration will be provided at 65% and at aluminum oxide will be cleaned
35% .
MONOTIG 220ip - MONOTIG 220ip AC/DC
www.magmaweld.com