WIrInG DIAGrAm
Codes 4-108854 and 4-108855 - fig.54/55
A1 ....................Control board RX2 BHD2SX
FU1 .................Primary of the transformer fuses 1A gG 10.3x38 (for the 400 V mains)
FU2 .................Fuses T 3A 5x20
F1 ....................Fuses T 2 A 5x20 (on board BHD2SX)
F2 ....................Blade fuse 10A (on board BHD2SX)
H1 ...................Luminous-acoustic indicator
HL1 .................White mains presence light
HL2 .................Lamp (optional)
KM1 - KM3 .....Power unit motor second speed remote switches
KM2 ................Power unit motor first speed remote switches
M1 ....................Hydraulic power unit motor
M2 ...................Turntable clamp motor
QS1 ..................Main switch
QS2 .................Emergency procedure manual command switch
QF1 .................M1 Motor thermal magnetic switch
TC1 ..................Transformer
YV1 .................Bypass solenoid valve
YV2 .................Turntable UP radial movement solenoid valve
YV3 .................Turntable DOWN radial movement solenoid valve'
YV4 .................LH arm translation solenoid valve
YV5 .................RH arm translation solenoid valve
YV6 .................Lift wheel solenoid valve
YV7 .................Lower wheel solenoid valve
YV8 .................Open turntable solenoid valve
YV9 .................Close turntable solenoid valve
YV10 ...............Lift tool arm solenoid valve
YV11 ...............Lower tool arm solenoid valve
YV12 ...............Tool LH rotation solenoid valve
YV13 ...............Tool RH rotation solenoid valve
YV14 ...............Bead breaker disc UP solenoid valve
YV15 ...............Bead breaker disc DOWN solenoid valve
XC1 .................Control lever cable connection connector
XS1 ..................Electrical plug
XT1 .................Terminal
Z1 ....................Network filter for turntable clamp motor
60
Operator's manual AGTT 1600A - AGTT 1600