The power unit motor does not start
No current
No current, provide power
The overload cut motor protector is not active
Activate the overload cut motor protector
Fuses burned
Check the primary of the transformer fuses and replace them if necessary
Check the fuses on the board and replace them if necessary
The power unit motor starts but the machine does not
Check the rotation direction of the hydraulic power unit motor
Union loose, tighten the union
Pipe cracked
Replace the pipe
Switch broken
Clean or replace the switch
Solenoid valve blocked
Clean or replace the solenoid valve
The distributor leaks
Replace the distributor
Gaskets worn
Replace the gaskets
Overload cut motor protector activated
Open the electrical board, set the main switch to 0 and then use the specific key to
reactivate the overload cut motor protector, operating the switch (fig.51); when complete,
reclose the electrical board.
52
TroUBlE SHooTInG
perform any commands
A control remains activated
Turntable cylinder pressure drop
motor stops during use
oil leak
Operator's manual AGTT 1600A - AGTT 1600