Appendix
Setting level
Self test
Network
¹ This menu item is not always displayed. Whether or not it is present depends on the unit type, the settings on the inverter, and the
firmware version.
² This menu item is always displayed. It is not possible to switch it off.
³ Can be set back to 0 via Main menu → Settings → Clear event log.
B
Overview of the event messages and troubleshooting
You can find explanations for the symbols and the types of event in the section Event message (→ Page 5).
B.1
Event message and troubleshooting
Event message
Data transfer failed
Grid islanding detected
Residual current too
high
Device overheated
Intern. info.
Intern. warning
Intern. error
14
Values
Unit
Min.
Max.
–
–
Symbol
Cause
A setting during the initial start-up has failed
because it was not transferred correctly.
The power grid carries no voltage (inverter
stand-alone operation).
For safety reasons, the inverter must not
feed into the power grid.
The inverter switches off while the fault is
present (display is dark).
The residual current that flows from the plus
or minus input via the PV generators to earth
exceeds the permitted value.
Due to normative specifications, the inverter
automatically switches off while the fault is
present.
Despite the reduction in output, the max-
imum permissible temperature has been
exceeded.
The inverter does not feed into the power
grid until the permissible temperature range
has been reached.
–
–
–
Increment, select, explanation
–
Results of the last Self test (only if the country
setting "Italy" has been set)
–
–
Host name: unique name in the network
–
DHCP status: DHCP on/off
→ On
→ Off
–
Link status: condition of the network connec-
tion
→ Connected
→ Not connected
–
IP address: IP address for the inverter
–
Subnet mask: subnet mask for the inverter
–
Gateway: IP address for the network gate-
way
–
DNS-Adresse: IP address for the DNS server
–
MAC address: hardware address for the
inverter
Measure
Implement the setting again.
Contact a competent person if the fault
continues to occur.
Contact a competent person if the fault
occurs more frequently.
Contact a competent person.
Check whether any objects are lying on the
product or whether the air circulation at the
cooling fins has been impaired.
If required, clean the cooling fins using com-
pressed air up to max. 2 bar.
Contact a competent person if the message
occurs more frequently.
Contact a competent person if the message
occurs more frequently.
Contact a competent person if the message
occurs more frequently.
Contact a competent person if the message
occurs more frequently.
Operating instructions VPV I 0020273404_00