Appendix
Setting level
Time format
Date format
Main menu → Settings → Energy management →
Mode ¹
Dyn. feed-in control ¹
PV-ready threshold
Configuration ¹
Main menu → Settings → Network →
DHCP
¹ This menu item is not always displayed. Whether or not it is present depends on the unit type, the settings on the inverter, and the
firmware version.
² This menu item is always displayed. It is not possible to switch it off.
³ Can be set back to 0 via Main menu → Settings → Clear event log.
12
Values
Unit
Increment, select, explanation
Min.
Max.
–
–
Selection options:
–
–
–
–
Selection options:
–
–
–
–
–
Selection options:
–
–
–
0
W
This sub-menu item is only displayed if the Ener-
gymeter mode has been selected.
Makes it possible to set the power that is fed into
the network in 10 W increments
300
5000
W
This sub-menu item is only displayed if the Ener-
gymeter mode has been selected.
The menu item allows for targeted supply of a
heat pump with excessive photovoltaic energy.
If the excess photovoltaic energy exceeds the
PV-Ready limit value, the wiring centre for feed-in
management sends a switch-on signal to the heat
pump.
Note
The PV-ready threshold function can only be
used in combination with an energy meter and a
wiring centre for feed-in management.
When defining the PV-Ready limit value, all of
the electrical consumers that are present in the
building must always be taken into consideration.
If a heat pump is installed, a set value for the
PV Ready limit value, which lies above the heat
pump's electrical connected load by 200 W, may
be useful, for example.
–
–
This sub-menu item is only displayed if the Ener-
gymeter mode has been selected.
Makes it possible to set the Meter type.
The factory setting is the Schneider iEM3155,
which is recommended by the manufacturer.
Selection options:
–
–
–
–
–
–
–
–
–
–
Automatic integration into an existing network
Selection options:
–
–
12h
24h
yyyy-mm-dd
dd.mm.yyyy
mm/dd/yyyy
off
Energymeter
Schneider iEM3155
Herholdt ECS3
Janitza ECS3
Herholdt ECS1
Janitza ECS1
B+G SDM630
B+G SDM220
Carlo Gavazzi EM24
On
Off
Operating instructions VPV I 0020273404_00
Default set-
ting
–
–
–
–
1000
Schneider
iEM3155
On