Inverter Control - gefran BDI50 Manuel D'utilisation

Compact v/f & sensorless inverter
Table des Matières

Publicité

4. Inverter Control

4.1 Command Data (Readable and Writable)
Register No.
2500H
2501H
2502H
2503~251FH
Note 1 : Write in zero for Not used BIT, do not write in data for the reserved register.
Note 2: Bit 2 of 2501H is not for fault indication. EFO is for "external abnormity." External
abnormity is any event not related to drive operation which can be defined
externally by the user/machine.
When there is external abnormity, user may change the bit value from 0 to 1
through communication, inverter will stop according to the setting in 07-09 (decel. to
stop or coast to stop).
Content
Bit
Reserved
Operation Signal
Operation Command
0
Reverse Command
1
Abnormal
2
Fault Reset
3
Jog Forward Command
4
Jog Reverse Command
5
Multi-function CommandS1
6
7
Multi-function CommandS2
8
Multi-function CommandS3
9
Multi-function CommandS4
A
Multi-function CommandS5
Reserved
B
C
Relay R1
D
Reserved
E~F Reserved
Frequency Command
Reserved
1 : Run
1 :Reverse
1 : EFO (Note)
1 : Reset
1 :
Jog Forward
1 :
1 :"ON"
App 3-5
0 : Stop
0 :Forward
Jog Reverse
1 :"ON"
0:"OFF"
1 :"ON"
0:"OFF"
1 :"ON"
0:"OFF"
1 :"ON"
0:"OFF"
1 :"ON"
0:"OFF"
0:"OFF"