2.2.2 100-240V Power Supply
Single-sided model:
- Strip the cable from the wall over 10 mm,
- Strip the two wires with a cross-section of 1.5 mm²
(maximum) over 5 mm,
- Position the cable and wires inside the female plug
of the supplied connector, checking:
• that the cable jacket penetrates the connector
sufficiently to ensure proper insulation,
(see image opposite),
• the direction of connection of the wires (phase and neutral),
- Screw the two screws onto each of the two wires to hold them in position,
- Connect the newly formed female plug to the male connector
movement.
Power supply (ref: 982 001).
For the double-sided model:
- Route the wiring through the bracket arm,
- Wire the first clock
A
- Wire the second clock
terminals of the first clock
For a double-sided Profil 930 / 940 model with two clocks, each with a power supply, you
must split the mains cable (with a split fitting) to then wire each of the two clocks like a
single-sided clock.
The procedure is similar if there are two mains cables: connect each clock as a
single-sided clock.
10
as a single-sided clock (see above),
by making a cascade connection to the + / - power supply, 6-24 V
B
.
A
A
Contact surface of the jacket/connector for insulation
Female Connector Socket
in the clock at the top right of the
1
1
B
EN