• Authentication failure: this parameter allows an alarm to be triggered when a user fails to
identify on the clock's web server.
• Periodic Status: this parameter allows you to check that the product is still in good working
order (in case alarms are "lost"). This verification is carried out at a set frequency.
• Low Wi-Fi Signal: indicates that the Wi-Fi signal is present but weak.
• Long Disconnection: Wi-Fi network lost for several days.
The alarm is triggered when the network is available again.
Information: the information reported is minor and does not require a visit from a service
technician to correct the fault.
Warning: the errors or failures reported are significant and require intervention by a
maintenance technician to correct the failure.
Critical: the errors or failures reported are serious and require urgent intervention by a
maintenance technician to correct the failure.
The "Save" button is used to save any settings entered on this page.
The "SNMP Trap test" button is used to send a status trap to all of the configured SNMP managers
to ensure that supervision is configured correctly.