TECHNICAL DATA

Operating conditions:
Operating temperature
Protection class
Conformity with following standards:
CE Mark
Mechanical data:
Dimensions
MiniTOP housing material
Sealing material MiniTOP
Pneumatic data:
Control medium:
Pressure dew point:
Oil content:
Dust content:
Temperature range of
the compressed air:
Pressure range:
Pressure output of the
control valve:
Connections:
Operating Instructions No. 803 925
0..+55°C
IP 65 according to EN 60529
Conformity with regard to the EMC
directive 89/336/EWG (only for correctly
connected cable and/or plug and
socket)
see data sheet
External PPE/PA, PSU; Internal PA 6
NBR
Instrument air,
Kl. 3 according to DIN ISO 8573-1
-20°C
max. 1 mg/m³
5µm filtered
0..+55°C
2..10 bar
40 l
/min (for aeration and ventilation)
N
(Q
value - according to definition for
Nn
pressure fall from 7 to 6 abs.)
1/8'' inner thread G / NPT / RC