UP 60
8
Commissioning
8.1
Connecting to Compressed Air Supply
DANGER!
Due to the risk of hand or finger injury, never try to reach into the machine before
having assured that the machine is disconnected from the air supply. Disconnect
the air supply before changing the safety guard, the adapter or the dies.
CAUTION!
The pneumatic Universal Crimp Machine UP 60 may only be set up and operated in
perfect technical condition, observing all the safety regulations and considering
any possible dangers.
The crimp machine is only allowed to be used with mounted dies, die adapter and
the suitable safety guard. Pay attention to the correct assignment of adapter to
safety guard.
The crimp machine is only allowed to be used when it is in complete functional
condition.
When working with the pneumatic Universal Crimp Machine UP 60, do not wear
loose clothing, jewellery or long, loose hair that can get caught in the pneumatic
Universal Crimp Machine UP 60.
Work with caution.
In cases of a machine malfunction, production must be stopped and the
malfunction must be fixed before continuing work with the machine.
Only one person is allowed to work on or with the machine.
Only trained personal are allowed to work on or with the machine.
Assure free access to the operating elements of the machine, especially the foot
pedal and the release button. In the case of imminent danger immediately press the
release button. The release button must be within the direct reach of the operator. It
must not be covered.
It is only allowed to work with the specified working pressure.
Page 49 / 104
TM-638018900 REV. B