3V-490072NU – 06/23
Green screen:
Information on the cooking
Non-blocking message
Touching the screen anywhere will
clear the message
Message on the screen
i28: Core probe: Faulty or missing when
cooking starts
E30:
Electronics overheating:
E32: Core probe: 2 sensors faulty
i33: Core probe faulty or missing whilst
cooking
i41: Lack of water detected: water is not
flowing from the spout
E43: Leak detected
i49: USB stick full or missing
EFr: Tank probe overheated
EFx: Tank base overheated (x = Number of
the zone)
ESx: Tank base probe short circuit or
disconnected (x = Number of the
zone)
ESb: Tank base probe short circuit or
disconnected
ESA: Tank base overheated
E72:
Electronics at
> 185°F
E90: Detection of tank tilt ram being
blocked
F49571 (07-23)
17
Client error information: ixx
Cooking stopped (pause)
Blocking message
Cooking will not start
Cooking continues automatically at a
(>158°F)
temperature below 356°F
Cooking continues.
Cooking stops
Cooking continues.
A cleaning cycle stops (Paused) or
automatic filling
Cooking continues.
USB stick full or USB awaited
Cooking stops
Cooking stops
Cooking stops
Cooking stops
Cooking stops
Cooking stops
If the tank can be returned to the horizontal
position the unit can be used for cooking
(without any movement of the tank)
Page 23
OPERATING FAULTS
Red screen:
Cooking stops
Consequences
After sales error information: Exx
Red screen:
Cooking stopped (pause)
Blocking message
Cooking stops
What to do?
To start cooking connect the probe or replace it if
necessary. Switch to timer mode if necessary. If the
problem persists, call your after sales service
Installation problem: check the proximity of a
heating unit to the right hand side.
If the problem persists, call your after sales service
Replace the core probe as soon as possible
If the problem persists, call your after sales service
To continue cooking connect the probe or replace it
if necessary. Switch to timer mode if necessary. If
the problem persists, call your after sales service
Check the water supply to the unit (Valve open,
pressure...).
If necessary, call your after sales service
Turn the water supply off and call your after sales
service
Clear the USB stick or connect another one.
If the problem persists, call your after sales service
Switch the appliance off and
service
Switch the appliance off and
service
Switch the appliance off and
service
Switch the appliance off and
service
Switch the appliance off and
service
Installation problem: check the proximity of a
heating unit to the right hand side.
If the problem persists, call your after sales service
Something is jammed under the tank preventing it
from moving: Clear it if you can.
If the problem persists, call your after sales service