3V-490072NU – 06/23
6.3
CLIENT PARAMETERS
6.4
PREVENTIVE MAINTENANCE
This message appears only when the appliance preventive maintenance is required (if the counter has been set in Installation parameter). The
customer will be automatically informed when service is needed. The service counter is a calculated function of the frequency of use and of the
number of hours between 2 services.
These values must be entered by the technician when installing the appliance and must be verified after every maintenance operation.
F49571 (07-23)
Page 11
Choice of default mode displayed
when first started
➔
Adjust the screen brightness and end
of cycle buzzer volume
Activation and adjustment of the
automatic pre-heat when the appliance
➔
is switched on.
Display Recipes by family (yes) or in
alphabetical order (no) By default: No
Activation of Screen standby after the
required time. Active outside the
current cycle. By default: Yes
➔
Country and temperature unit selection
Fill in the costs for energy and other products to calculate consumption. First press
➔
activates the cost area. The value can be change slowly with the knob. Second press
displays the keyboard to enter a value directly.
➔
After being exported to USB stick HACCP data prior to this number of weeks is deleted.
➔
Automatic screen locking
➔
Software reset (Attention: All recorded information is erased from memory: HACCP
data....)
Warning message
This message appears every time the appliance is switched on if the use time
programmed in the preventive maintenance counter is reached.
➔
Notify the maintenance department for an intervention as soon as possible
If the number of days falls to 0 or below, the message will be displayed in red and
indicates how many days past the scheduled maintenance date the appliance is.