Initial increment time
27
Lets you set the initial increment time.
Lets you automate the "crater filler" function.
Minimum
0.1 s
Crater filler time
28
Lets you set the "crater filler" time.
Lets you automate the "crater filler" function.
Minimum
0.1 s
Spot welding
30
Allows you to enable the "spot welding" process and establish the welding time.
Minimum
0.1 s
Pause point
31
Allows you to enable the "pause point" process and establish the pause time between one welding operation and
another.
Minimum
0.1 s
Initial increase slope
34
Allows to set a gradual transition between the initial wire speed and the welding wire speed.
Minimum
0 s
Crater filler slope
35
Allows to set a gradual transition between the welding wire speed and crater filler wire speed.
Minimum
0 s
Inductance
202
Allows electronic regulation of the series inductance of the welding circuit.
Makes it possible to obtain a quicker or slower arc to compensate for the welder's movements and for the natural
welding instability.
Minimum
-30
Compensated average voltage
331
Lets you set welding voltage.
500
Allows the selection of the required graphic interface.
Allows access to the higher set-up levels.
Refer to section "Interface personalisation (Set up 500)"
Value
USER
SERV
vaBW
Maximum
Default
99.9 s
0/off
Maximum
Default
99.9 s
0/off
Maximum
Default
99.9 s
0/off
Maximum
Default
99.9 s
0/off
Maximum
Default
10 s
0/off
Maximum
Default
10 s
0/off
Maximum
Default
+30
0/syn
Selected level
User
Service
vaBW