SETUP
500
Allows the selection of the required graphic interface.
EN
Allows access to the higher set-up levels.
Refer to section "Interface personalisation (Set up 500)"
Value
USER
SERV
vaBW
Lock/unlock
551
Allows the locking of the panel controls and the insertion of a protection code.
Refer to section "Lock/unlock (Set up 551)".
Buzzer tone
552
Permits adjustment of the buzzer tone.
Minimum
0/off
Current reading
751
Allow the real value of the welding current to be displayed.
Voltage reading
752
Allows the real value of the welding voltage to be displayed.
5.1.2 List of set up parameters (TIG)
Save and Exit
0
Allows you to save the changes and exit the set up.
Reset
1
Allows you to reset all the parameters to the default values.
Pre-gas
2
Allows you to set and adjust the gas flow prior to striking of the arc.
Permits filling of the torch with gas and preparation of the environment for welding.
Minimum
0/off
Initial current
3
Allows regulation of the weld starting current.
Minimum
1%
Initial current time
5
Minimum
0/off
Selected level
User
Service
vaBW
Maximum
Default
10
10
Maximum
Default
99.9 s
0.1 s
Maximum
Default
200%
50%
Maximum
Default
99.9 s
0/off
Minimum
Maximum
3 A
Imax
26
Default
-