Télécharger Imprimer la page

Bosch Climate 7000i Notice D'installation page 71

Masquer les pouces Voir aussi pour Climate 7000i:

Publicité

3.3
Unit installation
NOTICE
Incorrect assembly can cause material damage.
If the unit is assembled incorrectly, it may fall off the wall.
▶ Only install the unit on a solid flat wall. The wall must be capable of
supporting the weight of the unit.
▶ Only use screws and wall plugs that are suitable for the wall type and
weight of the unit.
3.3.1
Installing the indoor unit
▶ Determine the installation location, taking the minimum clearances
into consideration ( Fig. 4).
▶ Open the box at the top and lift the indoor unit out and up ( Fig. 8).
▶ Place the indoor unit with the moulded parts of the packaging face
down ( Fig. 9).
▶ Undo screw and remove the mounting plate on the rear of the indoor
unit.
▶ Attach the mounting plate centrally with the screws provided and
level out ( Fig. 10).
▶ Fasten the mounting plate with a further four screws and wall plugs
so that the mounting plate lies flat on the wall.
▶ Drill wall outlet for the piping ( Fig. 11).
To ensure proper water drainage, make sure that the outlet is drilled at a
slight downward angle, so that the outdoor end of the hole is lower than
the indoor end by about 5 mm to 7 mm.
▶ Place the protective wall cuff in the outlet to protect the edges of the
outlet and seal.
The pipe fittings on the indoor unit are generally located behind the
indoor unit. We recommend extending the pipes before mounting the
indoor unit.
▶ Establish pipe connections as described in Chapter 3.5.
▶ Bend the piping in the required direction if necessary, and knock out
an opening on the side of the indoor unit ( Fig. 14).
▶ After connecting the piping, proceed with the electrical connection
(Chapter 3.9).
▶ To connect the drain hose, refer to Chapter 3.5.3.
▶ Slowly route the wrapped bundle of piping, drain hose, and signal
wire through the hole in the wall, according to Chapter 6.
▶ Attach the indoor unit to the mounting plate ( Fig. 15).
▶ Using even pressure, push down on the bottom half of the unit. Keep
pushing down until the unit snaps onto the hooks along the bottom of
the mounting plate.
The unit should not jiggle or shift.
▶ Check that unit is hooked firmly on mounting by applying slight
pressure to the left and right-hand sides of the unit.
▶ Fold up the front cover and remove one of the two filter elements
( Fig. 16).
▶ Insert the filter which is included in the scope of delivery into the filter
element, and mount the filter element again.
If it is necessary to take the indoor unit off the mounting plate:
▶ Pull the underside of the casing down in the area of the two recesses
and pull the indoor unit forwards ( Fig. 17).
Climate 7000i – 6721873506 (2024/12)
3.3.2
Installing the outdoor unit
▶ Place the box facing upwards.
▶ Cut and remove the packing straps.
▶ Pull the box up and off and remove the packaging.
▶ Prepare and mount a floor or wall mounting bracket, depending on
the type of installation.
▶ Mount or hang the outdoor unit using the anti-vibration coupling for
the feet which is supplied with the unit or is provided on site.
For the different outdoor unit sizes and the distance between their
mounting feet, see Chapter 2.6.1.
▶ When installing on the floor or wall mounting bracket, attach the
supplied drainage elbow and gasket at the bottom of the unit
( Fig. 18).
▶ Anchor the outdoor unit to the ground or to a wall-mounted bracket
with a bolt (M10). Consider the unit dimensions in Table 17.
▶ Remove the cover for the pipe connections ( Fig. 19).
▶ Establish pipe connections as described in Chapter 3.5.
▶ Mount the cover for the pipe connections again.
3.4
Piping wrapping
To avoid condensation and water leakage, the connecting pipe must be
wrapped with tape to ensure isolation from the air.
2
1
Fig. 1
[1]
Drain hose
[2]
Signal wire
[3]
Refrigerant piping
[4]
Insulation material
▶ Bundle the drain hose, refrigerant pipes, and signal cable.
While bundling these items together, do not intertwine or cross the
signal cable with any other wiring.
▶ Make sure that the drain hose is at the bottom of the bundle. Putting
the drain hose at the top of the bundle can cause the drain pan to
overflow, which can lead to fire or water damage.
▶ Using adhesive vinyl tape, attach the drain hose to the underside of
the refrigerant pipes.
▶ Using insulation tape, wrap the signal wire, refrigerant pipes, and
drain hose tightly together.
▶ Double-check that all items are bundled.
▶ When wrapping the bundle, keep the ends of the piping unwrapped.
You need to access them to test for leaks at the end of the installation
process.
Installation
3
4
0010052294-001
71

Publicité

loading