1.3
Notices regarding these instructions
The figures are shown together at the end of these instructions. The text
contains references to the figures.
Depending on the model, the products may be different to those shown
in these instructions.
2
Product Information
2.1
Declaration of Conformity
The design and operating characteristics of this product comply with the
British, European and supplementary national requirements.
The UKCA and CE markings declare that the
product complies with all the applicable British and
European legislation, which is stipulated by
attaching these markings.
You can request the complete text of the Declaration of Conformity from
the UK address indicated in this document.
2.2
EU or GB Importer
Bosch Thermotechnology Ltd.
Cotswold Way, Warndon
Worcester WR4 9SW / UK
2.3
Simplified UK/EU Declaration of conformity
regarding radio equipment
Bosch Thermotechnik GmbH hereby declares, that the product Climate
7000i described in these instructions complies with the Directive UK
S.I. 2017/1206 (UK) 2014/53/EU.
You can request the complete text of the UK/EU Declaration of
Conformity from the UK address indicated in this document.
2.4
Regulations
In order to ensure installation and operation of the product in
accordance with the regulations, please observe all the applicable
national and regional regulations as well as all technical rules and
guidelines.You can find a list of the most relevant British and European
directives and regulations in the UK/EU Declaration of conformity.
2.5
Scope of delivery
Key to Fig. 3:
[1]
Outdoor unit (filled with refrigerant)
[2]
Indoor unit (filled with nitrogen)
[3]
Set of printed documents for product documentation
[4]
Fixing materials (5-8 screws and wall plugs)
[5]
Drainage elbow with gasket (for outdoor unit with floor or wall
mounting bracket) (may be attached to the outdoor unit upon
delivery)
[6]
Mounting plate
[7]
Remote control
[8]
5-core communication cable (optional accessory)
[9]
Remote control batteries (2)
[10] Remote control holder and fixing screw
[11] Magnetic ring
[12] Cold catalyst filter (black) and bio filter (green)
2.6
Product dimensions and minimum clearances
2.6.1
Indoor unit and outdoor unit
Figures 4 to 5.
2.6.2
Refrigerant lines
Key to figure 7:
[1]
Gas-side pipe
[2]
Liquid-side pipe
[3]
Siphon-shaped elbow as oil separator
Climate 7000i – 6721873506 (2024/12)
If the outdoor unit is installed higher than the indoor unit, a siphon-
shaped elbow must be installed on the gas side. The installation must be
done at intervals of no more than 6 meters, and every 6 metres
thereafter ( Figure 7, [1]).
▶ Observe maximum pipe length and maximum difference in height
between indoor unit and outdoor unit.
Outdoor Unit
Maximum pipe
length
CL7000i 20 E
CL7000i 26 E
CL7000i 35 E
CL7000i 41 E
CL7000i 53 E
1) Gas side or liquid side
2) Measured from lower edge to lower edge.
Table 2 Pipe length and difference in height
Outdoor Unit
Liquid side [mm]
CL7000i 20 E
6.35 (1/4")
CL7000i 26 E
6.35 (1/4")
CL7000i 35 E
6.35 (1/4")
CL7000i 41 E
6.35 (1/4")
CL7000i 53 E
6.35 (1/4")
Table 3 Pipe diameter depending on unit type
Pipe diameter [mm]
6.35 (1/4")
9.53 (3/8")
12.7 (1/2")
Table 4 Alternative pipe diameter
Specification of the pipes
Min. piping length
Additional refrigerant to be added if the
pipe length exceeds 5 m (liquid side)
Piping Thickness
Thickness of insulation against heat
Material of insulation against heat
Table 5
Product Information
Maximum difference
1)
2)
[m]
in height
[m]
≤ 25
≤ 10
≤ 25
≤ 10
≤ 25
≤ 10
≤ 25
≤ 10
≤ 30
≤ 20
Pipe diameter
Gas side [mm]
9.53 (3/8")
9.53 (3/8")
9.53 (3/8")
12.7 (1/2")
12.7 (1/2")
Alternative pipe diameter [mm]
6
10
12
3 m
With Ø 6.35 mm (1/4"):
12 g/m
≥ 0.8 mm
≥ 6 mm
Polyethylene foam
69