GARANT Tool24 Locker
de
Article no. 979320 Size 450/10
Length
1000 mm
Width
1200 mm
en
Height
2150 mm
Gross weight
210 kg
4.3.
TRANSPORT TO THE PLACE OF ERECTION
ü Prepare all the connection points at the final place of erection.
bg
ü The floor must have sufficient load-bearing capacity.
ü Forklift truck or pallet truck rated for the weight of the item of packaging.
ü The ambient conditions At the place of erection [} Page 16] must be correct.
1. Removing the packaging [} Page 16].
da
2. Remove the base fascia.
3. Drive the forklift truck forwards between the support pads of the goods issuing
system until they project beyond the far side.
»
Be aware of the position of the centre of gravity of the goods issuing system.
fi
4. Lift the goods issuing system from the pallet.
5. Transport the goods issuing system to its final place of erection.
6. Carefully lower the forks and withdraw them.
4.4.
REMOVING THE PACKAGING
fr
B
1. Remove the film packaging around the wooden frame; carefully dismantle the
transport frame.
it
2. Remove four to six screws from each side.
3. Take separately packed components off the pallet.
4. Remove the film packaging around the industrial vending system.
NOTICE! Carefully cut open the film packaging. Do not use any unsuitable
hr
cutting tools such as kitchen knives, decorator's knives or pocket knives.
5. At each corner of the industrial vending system, release four bolts to release it
from the pallet.
6. Dispose of the packaging correctly in accordance with local regulations.
lt
i
Cables and accessories supplied are mounted directly on the system or are bolted to
the pallet.
4.5.
AMBIENT CONDITIONS
nl
Store or erect the system indoors at a location dust-free, dry and not exposed to
sunlight, free from shaking and vibration.
Do not store or erect the system close to corrosive or aggressive chemical sub-
stances, solvents, moisture or dirt.
4.5.1.
Transport and storage
no
Temperature range
Relative atmospheric humidity (non-con-
pl
densing)
4.5.2.
At the place of erection
Temperature range
Relative atmospheric humidity (non-con-
pt
densing)
Lighting of the working environment
*Higher relative atmospheric humidity values are permissible at lower temperatures.
ro
5.
Assembly
5.1.
SETTING UP COMPARTMENTS WITH POWER SUPPLIES
Electrician
sv
i
Tool24 Locker equipped with 6-way socket strip. Access via the emergency access
duct.
sk
DANGER
Electric current
Risk of fatal electric shock.
»
Before starting any installation, cleaning or maintenance work, disconnect the
sl
device from the mains power supply.
»
Electrical installation, maintenance and repair may be performed only by trained
specialists.
»
For indoor use only.
es
»
If power cables or sockets are damaged, immediately disconnect the device from
the power supply, do not continue to use the device.
»
Do not drive over, pinch or crush cables.
»
Do not store liquids in the vicinity of electrically live components.
cs
»
Do not operate with wet or damp hands.
»
Check the power supply against the rated voltage and frequency shown on the
nameplate, and ensure they are identical.
1. Remove the emergency access duct [} Page 17].
hu
2. Actuate the mechanical release of the goods issuing flap.
16
Size 300/14
Size 180/40
1000 mm
1200 mm
1200 mm
1000 mm
2150 mm
2200 mm
200 kg
275 kg
-24 °C to +55 °C; briefly for max. 24h up to
+70 °C
max. 50 % at +40 °C
+5 °C to +40 °C
max. 50 % at + 40 °C*
at least 300 Lux
3. Use a screwdriver to break out the pre-prepared break-through in the goods issu-
ing compartment, and insert a cable grommet.
4. Insert a power supply unit or cable into the goods issuing compartment and feed
it through the break-through into the emergency access duct.
5. Fit strain relief in the region of the break-through.
6. Guide the power supply unit and cable downwards and out through the cable
exit.
7. Connect the power supply and start up the industrial vending system.
5.2.
MOUNTING THE SCREEN SUPPORT
1. Swivel the screen support round completely.
2. Route DVI cable through the cable outlet on swivel arm.
3. Guide all additional cables through cable outlet and mount screen support in
perforated panel.
4. Shift retaining plate upwards and tighten with integrated screws.
5. Press together cable holder and secure cables on the swivel arm.
6. After assembly and cabling, push remaining cables back into the slot.
»
Screen support has been installed.
6.
Preparation for use
6.1.
CONNECTING THE INDUSTRIAL VENDING SOLUTION
D
Electrician
ü The industrial vending solution has been unpacked.
1. Connect the power cable (mains cable) to the IEC C14 connector on the back of
the industrial vending solution.
2. Connect the network cable to the RJ-45 socket on the back of the industrial vend-
ing solution.
3. Connect the network cable to the network connection.
4. Connect the power cable to the socket.
»
The industrial vending solution has been connected.
6.2.
STARTING UP THE GOODS ISSUING SYSTEM
ü Close and lock the emergency access duct.
ü Connect the goods issuing system to the power supply.
ü Connect the main system (master) to the data network.
1. Switch on the monitor.
2. When the power supply is connected, the goods issuing system will start up
automatically.
»
The LED lighting strip will light up and the operating system is ready for use.
6.3.
CONNECTING THE SMARTLINE AS THE MASTER TO THE
LOCKER EXTENSION
E
Electrician
ü Locker extension has been positioned next to the Smartline master.
ü Industrial vending solutions have been disconnected from the power supply.
ü Smartline connected to the network.
ü Cover has been removed.
1. Remove the end cover from the cover.
2. Expose the opening for routing cables on the end cover.
3. Connect the data line from the USB-A output of the Smartline master to the USB-
A input of the Locker extension.
4. Connect power cable to power supply via IEC C14 connector.
5. Mount the end cover with protective cable bushing on the cover.
6. Fit the cover.
7. Restore the power supply.
8. Switch on the industrial vending solution and interconnect the systems in the
software.
»
Smartline master has been connected to the Locker extension.
6.4.
CONNECTING THE PICKONE AS THE MASTER TO THE LOCKER
EXTENSION
F
Electrician
ü Locker extension has been positioned next to the PickOne master.
ü Industrial vending solutions have been disconnected from the power supply.
ü PickOne base fascia has been removed.
1. Connect the data line from the USB-B output of the PickOne master to the USB-A
input of the Locker extension.
2. Connect power cable to power supply via IEC C14 connector.
3. Restore the power supply.
4. Switch on the industrial vending solution and interconnect the systems in the
software.
»
PickOne master has been connected to the Locker extension.