1
Check the engine oil level before each use or every 8
hours of operation.
P
the generator on a level surface and allow the
engine to cool for several minutes.
Remove the oil dipstick and wipe the dipstick clean.
See Figure 2 Insert, then remove the oil dipstick.
Acceptable Oil Level –
Low Oil –
2
4.
engine oil incrementally and check until the level is at
top notch on the dipstick, drain the oil to reduce the oil
level to the full mark.
5.
ENGINE OIL CHANGE
When using the generator in dusty conditions or
extremely hot weather, change the oil more frequently.
Change the oil while the engine is still warm from
operation.
1. P
the generator on a level surface and allow the
engine to cool for several minutes.
2.
3.
P
an oil pan (or suitable container)
drain hose.
MAINTENANCE
3
Unclip the oil drain hose and twist the cap
counterclockwise to allow the oil the to drain.
Twist the cap clockwise to close. Secure the hose in the
hose clip.
See Figure 4 Place the oil pan uder the oil filter. Remove
the oil filter by rotating it counterclockwise. Allow the oil
to drain completely. Clean the area where the oil filter
contacts the engine.
4
7. Apply clean oil to the rubber seal on the new oil
contacts the engine then turn another 3/4 turn. DO NOT
overtighten.
8. See Figure 5 Fill with the recommended oil. Stop
frequently to check the oil level. Do not overfill. If the
engine is overfilled, the excess oil may get transferred
to the air cleaner housing and air filter. An indication of
overfilling is white or blue smoke coming from the
muffler when the engine is running.
5
Maximum oil capacity: 1.7 Quart (1.6 Liter)