Power indicator light
Energy efficiencý per gas burner EE
gas burner
DESTINATION
GAS CATEGORY
COUNTRY
FRANCE
Cat II 2E+3+
SPAIN
Cat II 2H3+
PORTUGAL
Cat II 2H3+
Burner
specifications
Large burner
Medium burner
Small burner
Burner
specifications
Large burner
Medium burner
Small burner
WARNING: the values supplied with the appliance or the accompanying documents are
laboratory values which comply with the respective standards. These values may vary according
to use and ambient conditions.
G20/G25, 20/25 mbar
G20, 20 mbar
G20, 20 mbar
G20, 20 mbar
G25, 25 mbar
Natural gas
Injector
1.15
Consumption
0.276
Power
2.90
Injector
0.97
Consumption
0.162
Power
1.70
Injector
0.72
Consumption
0.96
Power
0.95
G30, 28–30 mbar
G31, 37 mbar
LPG
Injector
0.85
Consumption
211
Power
2.90
Injector
0.65
Consumption
124
Power
1.70
Injector
0.50
Consumption
69
Power
0.95
Front left auxiliary cooking zone
Rear left semi-fast cooking zone
Front right fast cooking zone
Rear right semi-fast cooking zone
NG
G20, 25 mbar
Natural gas
mm
1.10
m
/h
0.276
3
kW
2.90
mm
0.92
m
/h
0.162
3
kW
1.70
mm
0.70
m
/h
0.96
3
kW
0.95
G30, 50 mbar
LPG
mm
0.75
g/h
211
kW
2.90
mm
0.60
g/h
124
kW
1.70
mm
0.43
g/h
69
kW
0.95
7
No
0.95 kW
1.7 kW
2.9 kW
1.7 kW
LPG
G30/G31, 28–30/37 mbar
G30/G31, 28–30/37 mbar
G30/G31, 28–30/37 mbar
G20, 13 mbar
Natural gas
mm
1.45
mm
m
/h
0.276
m
3
kW
2.90
kW
mm
1.10
mm
m
/h
0.162
m
3
kW
1.70
kW
mm
0.85
mm
m
/h
0.96
m
3
kW
0.95
kW
G30, 37 mbar
LPG
mm
0.85
mm
g/h
211
g/h
kW
2.90
kW
mm
0.65
mm
g/h
124
g/h
kW
1.70
kW
mm
0.50
mm
g/h
69
g/h
kW
0.95
kW
EN
/h
3
/h
3
/h