5.5.2
Connecting interfaces
6
Commissioning
6.1
Checking
8021265/1OPE/2024-10-09 | SICK
Subject to change without notice
NOTE
The motor feedback system enables a radial output
electrical connecting cables (9), (11).
Open the cover (1) using a screwdriver, if necessary (Diagram A).
While de-energized, insert the male connector (8) into the female connector (10). If
necessary, while de-energized, insert the male connector (11) into the female connec‐
tor (12).
Table 2: Male/female connector position
Type
DSL
Temperature
Lead the DSL cable (9) and, if applicable, temperature sensor cable (11) out taking into
account the cutouts in the housing (2) and cover (1).
Close the cover (1).
Commissioning the safe motor feedback systems requires that the manufacturer of the
connected drive system has complied with the safety requirements for the drive system
design, as described in the "HIPERFACE DSL
Ensure that an EES37-2 / EEM37-2 safe motor feedback system and not an EES37-0 /
EEM37-0 standard motor feedback system is being used during commissioning. This
must be verified by reading out the type name (resource 083h). In addition, the POST
bit (Power-On-Self-Test) must be set for a EES37-2 / EEM37-2 safe motor feedback
system after an encoder RESET (hardware or software RESET). The POST bit can be
acknowledged after a positive thorough check (see "HIPERFACE DSL
mentation manual).
If the position offset of the motor feedback system is changed using the 101h ("Set
position") resource or the 108h ("Factory settings") resource, it is then necessary to
verify that the sensor is providing the required position value.
Further inspection measures are not required during operation.
WARNING
The safe motor feedback system has a maximum mission time
time, it must be taken out of service.
The motor feedback system's construction year can be found in the serial number (SN)
on the device label or on the packaging label (YYWW).
YY = represents the year (without century)
WW = represents the calendar week of the last manufacturing process.
OPERATING INSTRUCTIONS
(see figure 2, page
Male connector
10
12
®
Safety" implementation manual.
O P E R A T I N G I N S T R U C T I O N S | EES37-2...
27) of the
Female connector
8
11
®
Safety" imple‐
(section
9). After this
29
EEM37-2...
en

Publicité

loading