5
Electrical installation
5.1
Shielding connection
5.2
Connecting interfaces
8021265/1OPE/2024-10-09 | SICK
Subject to change without notice
1
á
à
ß
8
9
Figure 2: Mounting/removing the conical shaft
No.
Designation
Cover
1
Encoder
2
Centering collar
3
Code disc cone
4
Fastening straps
5
M3 fixing screw
6
Cone fixing screw
7
NOTE
Observe the corresponding operating instructions of the external drive system or the
higher-order control system for the installation of the motor feedback system.
NOTE
Make sure the affected machines/systems are in a de-energized state during mounting!
NOTE
A suitable encoder shield connection to the ground or to the motor shield is required for
smooth operation.
The encoder is connected to the motor housing via the screws (2).
Open the cover (1) using a screwdriver if necessary.
►
While de-energized, insert the male connector (8) for the set of stranded wires (9)
►
into the female connector (10) on the encoder far enough that it clicks into place.
Close the cover (1) so it engages properly.
►
You should be able to feel and hear it click into place.
►
OPERATING INSTRUCTIONS
7
6
ã
2
â
5
4
3
No.
Designation
DSL male connector
8
DSL cable
9
DSL female connector
ß
Temperature sensor male connec‐
à
tor
Temperature sensor female con‐
á
nector
Temperature measuring point
â
Measurement point for shock and
ã
vibration load
O P E R A T I N G I N S T R U C T I O N S | EES37-2...
en
27
EEM37-2...