8.4. PROGRAM
Configuration settings are stored in non-volatile memory. Access to each submenu is protected
with passcode. To enter configuration menu, hold
storing values is helped by flashing cursor.
STOP button increments selected digit by one, cycles between options, or scrolls to the next
screen when the cursor is at the '>' symbol.
Configuration menu layout is shown below.
MENU
SETTINGS
1. SETTINGS AND CALIBRATION PASSCODE PROMPT
1.0 Language
1.1 High pressure pump delay, s
1.2 Forward Flush 1 duration, s
1.3 Forward Flush 2 duration, s
1.4 High pressure pump power during Forward Flush 2, on/off
1.5 Frequency of periodic Forward Flush in Service, h
1.6 Frequency of periodic Forward Flush in Standby, h
1.7 Read low feed pressure during Forward Flush, on/off
1.8 Low feed pressure switch, NO/NC
1.9 Low feed pressure Fault delay, s
1.10 High feed pressure switch, NO/NC
1.11 Permeate backpressure switch, NO/NC
1.12 Backpressure Standby delay, s
1.13 Tank level switch, NO/NC
1.14 Tank level Standby delay, s
1.15 Display TDS in ppm
1.16 Permeate conductivity Fault threshold, μS/cm
1.17 Permeate conductivity Fault delay, s
1.18 New settings and calibration passcode
2. SETTINGS AND CALIBRATION PASSCODE PROMPT
2.1 First point value, μS/cm
2.2 Second point value, μS/cm
3. MAINTENANCE PASSCODE PROMPT
3.1 Schedule maintenance stop, on/off
3.2 Scheduled stop period, h (if 3.1 is set to 'on')
3.3 New maintenance passcode
*Before first start of the system change the high pressure pump delay at 255 sec to release the air from the
unit, after successful running of RO unit come back to the factory setting of 10 sec.
This manual is the intellectual property of Ecosoft. Copying and reprinting is prohibited. © 2017
INSTRUCTION MANUAL ECOSOFT RO SYSTEM MINI (MO-6500, MO-12000, MO-24000)
STOP for 8 seconds. In the menu, editing and
START button moves cursor one position to the right,
FACTORY SETTING
МО6500/МО12000
МО24000
0000
English
10* sec
60 sec
0 sec
off
4 hour
24 hour
on
NC
3 sec
NO
NC
1 sec
NC
1 sec
off
0 μS/cm
0
-
0000
-
-
0000
off
500 hour
21
NO