To replace membrane element proceed as follows:
• remove the power from the unit;
• shut off water supply and relieve pressure;
• disconnect feed, permeate, and concentrate tube connections at membrane module
outlets;
• unfasten clamps holding the pressure vessel and take down the vessel;
• remove caps from the pressure vessel;
• push the membrane element from the feed end towards the discharge end (in the
direction of the arrow). Extract the membrane element by pulling it at the discharge end
of the vessel;
• install new membrane element, observing flow direction as indicated by the arrow;
• fasten the caps and install the vessel back in place;
• re-connect tubes back to the vessel.
Do not perform any maintenance, repair, cleaning, moving the unit or ancillary units
(permeate tank, media filters etc), when the unit is connected to power and water
supply.
Do not subject pressure vessel to mechanical impact (shocks, static load etc).
The manufacturer shall not be held liable for any damages incurred by the owner of the
unit or any third party due to failure to adhere to the safety precautions or installation
guidelines herein.
6. SHIPPING AND STORAGE REQUIREMENTS
•
The unit must be stored indoors. Ambient air quality must meet workplace standards.
•
Carry out preservative treatment of membrane elements when preparing for an extended
downtime.
•
The RO machine in its original packaging can be shipped by all types of air, sea or ground
transport.
•
During transportation, the unit must be protected from exposure to low temperatures
and jolts/vibration.
This manual is the intellectual property of Ecosoft. Copying and reprinting is prohibited. © 2017
INSTRUCTION MANUAL ECOSOFT RO SYSTEM MINI (MO-6500, MO-12000, MO-24000)
11