8.2. TECHNICAL DATA
Table 1. Specifications
Electrical rating
Power
IP code
Ambient temperature
Weight
Dimensions (L×W×H)
Permeate conductivity ranges
Table 2. Screw terminal pinout
DESCRIPTION
Live
Neutral
Ground
Conductivity meter
Temperature sensor
Pressure switch before pump
Pressure switch after pump
High permeate pressure switch
Level switch
Stop switch
Magnetic starter of high pressure pump
Alarm signal
Entry valve
Forward flush valve
Bypass valve
*Power supply 115 V, 60 Hz for request
This manual is the intellectual property of Ecosoft. Copying and reprinting is prohibited. © 2017
INSTRUCTION MANUAL ECOSOFT RO SYSTEM MINI (MO-6500, MO-12000, MO-24000)
POWER
230 V*
INPUTS
5 V 1 mA
dry contact
(NC/NO)
OUTPUTS
230 V*
230 V, 50 Hz*,
2 x fuse 2 A
4 VA
IP 65
+5...+40 °C
0,25 kg
60 × 120 × 250 mm
0...1000 μS/cm
DESIGNATOR
PIN #
L
35
N
34
33
1 — white
cond
2 — black
3 — red
+ temp −
4 — green
5 — blue
P_in
8–9
P_max
10–11
P_perm
12–13
level
14–15
stop
6–7
31–32
pump
30 (ground)
alarm
28–29
18–17 (NO)
InValve
18–19 (NC)
16 (ground)
22–21 (NO)
Rinse_Valve
22–23 (NC)
20 (ground)
26–25 (NO)
Bypass_Valve
26–27 (NC)
24 (ground)
15

Publicité

loading

Ce manuel est également adapté pour:

Mo-6500Mo-12000Mo-24000P0090626P0090627P0090628