INSTRUCTION MANUAL ECOSOFT RO SYSTEM MINI (MO-6500, MO-12000, MO-24000)
22
1. Settings
Hold
STOP for 8 seconds to launch menu prompt. Push
Enter passcode in the prompt. Factory passcode is '0000'.
1.0 Language
Choose language to display operation information & menu. Avialable languages include English
& Russian.
1.1 High pressure pump delay
Enter length of interval between opening the entry valve and starting the pump when the unit is
going into Service (0...255 seconds).
1.2 Forward Flush 1 duration
Enter length of Forward Flush 1 (0...255 seconds). Forward Flush 1 will not be performed if the
parameter is set to zero.
1.3 Forward Flush 2 duration
Enter length of Forward Flush 2 (0...255 seconds). Forward Flush 2 will not be performed if the
parameter is set to zero. Default setting is zero (Forward Flush 2 disabled).
1.4 High pressure pump power during Forward Flush 2
This setting specifies whether the high pressure pump will be powered during Forward Flush 2
(on/off).
1.5 Frequency of periodic Forward Flush in Service
This setting determines how often Service mode is interrupted to run forward flush sequence
(once in 0...255 hours).
1.6 Frequency of periodic Forward Flush in Standby
This setting determines how often Standby mode is interrupted to run forward flush sequence
(once in 0...255 hours).
1.7 Read low feed pressure during Forward Flush
This setting specifies if low feed pressure switch status will be read by the controller during
forward flush. If set to 'off', low feed pressure situation will not bring about Fault mode.
1.8 Low feed pressure switch
This setting specifies whether low feed pressure switch is normally closed (NC) or normally open
(NO) type.
1.9 Low feed pressure Fault delay
Specify the length of time before the controller goes into Fault mode if low feed pressure condition
occurs (0...255 seconds). The pump will continue to run for this many seconds before Fault mode is
switched to. If set to 0, pump will stop running immediately after low feed pressure occurs.
This manual is the intellectual property of Ecosoft. Copying and reprinting is prohibited. © 2017
START to enter Settings submenu.