Télécharger Imprimer la page

BWT ECOSOFT MINI Instructions De Montage Et D'utilisation page 38

Système d'osmose inversero system

Publicité

INSTRUCTION MANUAL ECOSOFT RO SYSTEM MINI (MO-6500, MO-12000, MO-24000)
3.9
Let the unit run for 1 hour discarding permeate and concentrate to drain to flush out
membrane preservative. Watch pressure and flow rate readings to make sure these do not exceed
requirements.
After 1 hour of operation, start forward flush cycle (by pressing START on controller front panel),
then stop the unit. Switch off main circuit breaker. Connect permeate tube/hose to permeate tank.
The RO system is ready for operation.
4. INSTALLATION REQUIREMENTS
Installation and setup of the unit should be undertaken by a qualified professional. Room
or area where the unit is to be installed must meet workplace standards of local building code.
The unit must not be operated in outdoor environments. Do not expose to weather
conditions (rain, temperature fluctuations, proximity of heating equipment, direct sunlight etc).
Air at workplace should be free of corrosive vapors, airborne dust, and fibrous matter.
To provide access to the unit for maintenance and repair purposes, respect the following
clearances between the unit and building structures: 500 mm to the left or right, 200 mm above.
Electrical connections must comply with local electrical code. Make sure to follow
applicable grounding and insulation rules.
Supply, drain, and delivery pipework must comply with local plumbing code and have
sufficient flow capacity. Drain line of the unit must be separated from floor drain with an air gap.
Construction material or inside lining of permeate tank must be resistant to water
corrosion (e. g. stainless steel, polypropylene). Tank should be installed next to the unit.
Antiscalant pump suction line length should not exceed 1,5 m. Refer to dosing pump's
manual to adjust pump's settings if it has not been factory configured.
5. OPERATING REQUIREMENTS
5.1
Operator of the unit must strictly follow these guidelines and general electrical safety
precautions.
If power supply cord is damaged, it must be replaced by the manufacturer, its service
agent or similarly qualified person in order to avoid hazard.
5.2
When operating the unit, ensure that pressure and flow rates are within specification
limits and that power supply is clean and uninterrupted.
5.3
Perform the following at least once a month:
• verify that readings on pressure gauges and rotameters fall within the specified range per
requirements specification;
• verify tightness of hydraulic connections and integrity of parts.
This manual is the intellectual property of Ecosoft. Copying and reprinting is prohibited. © 2017
9

Publicité

loading

Ce manuel est également adapté pour:

Mo-6500Mo-12000Mo-24000P0090626P0090627P0090628