INSTRUCTION MANUAL ECOSOFT RO SYSTEM MINI (MO-6500, MO-12000, MO-24000)
2.2. TECHNICAL DATA
Table 1. Physical data
Model
Code
M6VCTFW
Rated capacity, LPH*
Membranes
1 × XLE-4040 2 × XLE-4040
Pressure inlet, bar
Water consumption, L
Power consumption, kW
Dimensions (W×D×H), mm
Maximum dry weight, kg
Connection port sizes:
• feed water
• permeate
• drain
Operating specification**
Recycle flow rate:
• LPM
• LPH
Drain flow rate:
• LPM
• LPH
Permeate flow rate:
• LPM
• LPH
* t= 25⁰С, TDS=1000 mg/l
** Feed water must comply with requirements in Table 2. If some data are not
available or do not meet requirements, contact Ecosoft product support.
Tap feed water must be pre-filtered from fine particulates and residual chlorine before
entering the RO system. Well water may contain impurities such as hardness, iron,
manganese, silica, hydrogen sulfide that can quickly lead to membrane failure. Some of
these challenges can be addressed by using injection of antiscalant. Perform a detailed
laboratory analysis of your well water and consult a water treatment specialist to see if
you need additional equipment for treating your well water.
This manual is the intellectual property of Ecosoft. Copying and reprinting is prohibited. © 2017
MO-6500
MO-12000
MO-24000
M10VCTFW M24VCTFW
280
530
1000
4 × XLE-4040
2–6
30–38
58–75
0,67
1,9
700 × 610 ×
540 × 405 × 1450
1450
60
70
100
1/2"
1,0"
1/2"
1,0"
1/2"
1,0"
13–15
8,2–11,2
21–35
820–900
490–680
1200–2100
1,2–1,7
2,2–3,0
5–8
70–100
130–180
300–500
3,5–4,5
6,5–9,0
16–20
200–270
390–540
900-1200
Table 2. Limitations***
150 mg/l CaCO
Hardness
8,5 °dH
Iron
0,1 mg/l
Manganese
0,05 mg/l
Silicate
20 mg/l
Total dissolved
3000 mg/l
solids
Chemical oxygen
4,0 mg/l O
demand
Residual chlorine
0,1 mg/l
Hydrogen sulfide
none
***The limitations may be exceeded if
using antiscalant, oxygen scavenger,
or other RO chemical pretreatment.
Inlet pressure
0,2...0,4 MPa
Temperature of
10...25 °C
water
Electrical power
230 V, 50 Hz
Membrane
0,8...1,2 MPa
pressure
5
3
2