UNITS INSTALLATION
¡
Fix Unit to the wall
1. Fix the Unit onto the wall as the
figure indicates. (field supplied
stay)
2. Ensure the foundation so that
avoid the deforming and noise.
3. In case of prevention from
vibration transfer to the building,
use rubber Mat.
¡
Suspended unit
1. Suspend the unit as the drawing
indicates.
2. Ensure that wall can resist the
Outdoor unit weight indicated in
specification label plate.
3. It is recommended to select each
foot support to bear the full weight
of the unit (in order to consider
stress fatigue applied when unit is
working too).
¡
Installing location where the unit will be exposed to strong wind.
Follow the instructions below to install
on the rooftop or a location without
surrounding buildings, where strong
wind is expected against the product.
1. Choose a location where the outlet
or inlet side of the product will not
be exposed to strong wind.
2. When the outlet is exposed to
strong wind:
Direct strong wind may cause lack
of air flow and adversely affect to
the operation.
10.2. INDOOR UNIT INSTALLATION
NOTE:
- Install the unit in area that does not affect other elements if
the drain valve blow-off.
- It's recommended to install the unit in frost free location.
- Two people are required to mount the unit.
WARNING:
- Check to ensure that the accessories are packed with the
indoor unit.
- Do not install the indoor units outdoors. If installed
outdoors, an electrical hazard may occur.
- Do not install the indoor units where electromagnetic
waves are directly radiated to the electrical box.
- Install the indoor units and components as far as practical
(at least 3 meters) from all sources of electromagnetic
wave radiations.
PMML138A_R1-eng-fre.indb 23
Rubber
Material
(Field
Supplied)
Wall bracket (*)
Anchor Bolts (*)
(*) Field supplied
- Install noise filter when the power supply emits harmful
noises.
- Do not install the Indoor Unit in a flammable environment to
avoid fire or an explosion.
- AquaFREE Must be installed by a technical service.
AquaFREE installation must comply with local and
European regulations.
CAUTION:
- The control of the temperature is only available through the
room's thermostat or Aquastat. The Remote Control Switch
of the indoor unit cannot be touch, if it is done the unit will
be outside of warranty.
Mark
Dimension
4~5H(V)
Model
3HVRNME
RNME
A (mm)
529
796
CAUTION:
Pay attention to the following for
installation:
1. Installation shall ensure that outdoor
unit will not incline, vibrate, make
noise or fall down by a blast of
wind or in an earthquake. Calculate
quake-resistance strength to
ensure that installation is strong
enough against falling. Fix the unit
with wires (field supplied) when
installing in a location without walls
or windbreak and likely exposed to
a blast of wind.
2. To use a vibration-proof mat, fix four
places to the front and back.
CAUTION:
Excessive strong wind against the
outdoor unit outlet may cause inverse
rotation and damage the fan and
motor.
PMML0138A-rev.1 - 11/2009