1.3. Preliminary checks

1.3.1. Installation environment

ATTENTION
Do not spray water onto the motorisation.
Do not install the motorisation in an explosive environ-
ment.
Check that the temperature range marked on the motori-
sation is suited to the installation location.

1.3.2. Condition of the gate to be motorised

Do not motorise a gate which is in poor working order or has
been incorrectly installed.
Before installing the motorisation, check that:
• the gate is in good mechanical condition
• the gate is stable regardless of its position
• the structures supporting the gate allow the motorisation
to be fixed securely. Strengthen these if necessary.
• the gate can be opened and closed properly using a force
of less than 150 N.

1.4. Risk prevention

WARNING
Risk prevention - motorisation of a hinged gate for
residential use
Ensure that any danger zones (crushing, cutting, trapping)
between the motorised section and the surrounding fixed
sections created by the opening of the motorised section
are avoided or indicated on the installation.
Permanently affix the crushing warning labels near to any
fixed control devices or so that they are clearly visible to
the user.
Copyright
©
2018 SOMFY ACTIVITES SA. All rights reserved.
Zone 3
Zone 2
Zone 1
Zone 5
Zone 4
Risk zones: measures to be taken to eliminate risks.
RISK
SOLUTION
ZONE 1
Obstacle detection built into the
motorisation. Obstacle detection
Risk of crushing
must be confirmed as being compli-
during closing
ant with Appendix A of standard EN
12 453.
For operation with automatic clos-
ing, install photoelectric cells.
ZONE 2
Obstacle detection built into the
motorisation. Obstacle detection
Risk of cutting or
must be confirmed as being compli-
crushing between
ant with Appendix A of standard EN
the gate leaf and
12 453.
any adjoining fixed
sections
Protection via safety distances (see
figure 1)
ZONE 3
Obstacle detection built into the
motorisation. Obstacle detection
Risk of crushing
must be confirmed as being compli-
with an adjoining
ant with Appendix A of standard EN
fixed part upon
12 453.
opening
Mechanical protection (see figure 2)
Eliminate any gap ≥ 8 mm or ≤
25 mm
ZONE 4
Obstacle detection built into the
motorisation. Obstacle detection
Risk of jamming
must be confirmed as being compli-
between the sec-
ant with Appendix A of standard EN
ondary edges and
12 453.
the adjoining fixed
parts
Eliminate any gap ≥ 8 mm or ≤
50 mm
ZONE 5
Obstacle detection built into the
motorisation. Obstacle detection
Risk of cutting be-
must be confirmed as being compli-
tween the arms, the
ant with Appendix A of standard EN
arms and the motor
12 453.
cover.
Protection via safety distances (see
Risk of crushing
figure 1)
between the arms
and gate
No protection is required if the gate has continuous control
or if the danger zone is more than 2.5 m above ground or any
other permanent access level.
Figure 1 - Safety distance
Figure 2 - Mechanical protection
Deformable cover
ensuring a safety
distance of 25 mm
in the compressed
position
EN
Profile
3