Water Supply Requirements
W
E
(within 1/2" of rear wall)
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed
here.
IMPORTANT:
� Connect to a potable water supply only.
Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after
the system. Systems certified for cyst reduction may be used
on disinfected waters that may contain filterable cysts.
� All installations must meet local plumbing code requirements.
� Do not use a piercing-type or 3/16" (4.76 mm) saddle valve
which reduces water flow and clogs more easily.
NOTE: Your refrigerator dealer has a kit available with a 1/4"
(6.35 mm) saddle-type shutoff valve, a union, and copper or
braided stainless steel or PEX tubing. Before purchasing,
make sure a saddle-type valve complies with your local
plumbing codes.
� Check for leaks. Install water supply lines only in areas where
the household temperatures will remain above freezing.
NOTE: Refrigerator is having 3/4" (19 mm) NPT solenoid
connection. It is recommended to use only 1/4" quick connect
elbow adapter for 1/4" copper or polyethylene source water
line to the refrigerator, or an appropriate NPT adapter.
� For models with water filters, the disposable water filter should
be replaced at least every 6 months.
E
W
E
W
W
E
Water shutoff
Access hole
Water Pressure
A cold water supply with water pressure of between
20 psi and 120 psi (137.9 kPa and 827.4 kPa) is required to
operate the water dispenser and ice maker. If you have questions
about your water pressure, call a licensed, qualified plumber.
IMPORTANT: Flush the water system before calibrating
Measured Fill.
Reverse Osmosis Water Supply
IMPORTANT: The pressure of the water supply coming out of a
reverse osmosis system going to the water inlet valve of the
refrigerator needs to be between 20 psi and 120 psi
(137.9 kPa and 827.4 kPa).
If a reverse osmosis water filtration system is connected to your
cold water supply, the water pressure to the reverse osmosis
system needs to be a minimum of 20 psi to 120 psi
(137.9 kPa to 827.4 kPa).
If the water pressure to the reverse osmosis system is less than
20 psi to 120 psi (137.9 kPa to 827.4 kPa):
� Check to see whether the sediment filter in the reverse
osmosis system is blocked. Replace the filter if necessary.
� Allow the storage tank on the reverse osmosis system to refill
after heavy usage.
� If your refrigerator has a water filter, it may further reduce the
water pressure when used in conjunction with a reverse
osmosis system. Remove the water filter. See "Water Filtration
System".
If you have questions about your water pressure, call a licensed,
qualified plumber.
INSTALLATION INSTRUCTIONS
Opening Dimensions
6" Upper
furniture
return
Soffit
25"
Minimum
6"
Furniture
return
84"
30"