GB Reset with setting switch and switch
6. Reset with setting switch and switch
Reset with
setting switch
1 s
Reset with switch
5x 3 s with 1 s pause
Precondition: Both end positions must be set, this means, the drive does no longer
make any moving interruptions during operation. For the reset with a switch, the upper
end limit position must be set on stop with relief.
Drive
Connect the setting switch cable to the motor wiring cable.
Press the E button of the setting switch for 1 second. Both
limit positions already set will be deleted.
Start the setting of the end limit positions once again
(4.5.1. to 4.5.3.).
Drive
Move the drive upwards until it stops automatically at the
upper limit stop and performs a short release.
Then press the switch 5 times for 3 seconds with
1 second pause in upwards direction.
Then turn on the upward direction again. The drive moves
down and switches off automatically. Now turn off the
switch. Both limit positions already set will be deleted.
Start the setting of the end limit positions once again
(4.5.1.).
34