Installation and electrical connection
3.3. Assembly and disassembly of the pluggable cable
The pluggable cable is not yet implemented for all motor types; some motor types are
still supplied with a fixed cable.
Caution! Risk of injury through an electric shock!
When the pluggable cable is unplugged, the line must be de-energised!
Warning!
For installing the pluggable cable, de-energise the pluggable cable first. Insert the plug
into the motor head until the lock engages audibly.
For uninstalling the pluggable cable, de-energise the pluggable cable first. Open the
plug lock through the lateral opening at the motor head. This can be done with a
screwdriver or a special release tool. Press on the locking clip from both sides and
carefully pull out the pluggable cable until the plug comes loose and the pluggable
cable can be removed.
3.4. Electric connection
1 = PE, yellow-green
2 = DOWN, black
3 = UP , brown
4 = N, blue
27
GB
GB