Télécharger Imprimer la page

Olsberg VESTA 6 KW Instructions De Montage page 56

Publicité

Les langues disponibles

Les langues disponibles

Operating manual
EN
for the user
CLEANING
Minor cleaning: "Minor cleaning" is carried out every hour
takes a short time. The screw motor is switched off and the
flue exhauster runs at maximum speed. The burner trough is
thus cleaned. Heating operation automatically continues.
Major cleaning: "Major cleaning" is carried out every eight
hours. Here, the combustion process is stopped. The screw
motor is switched off and the flue exhauster runs at maximum
speed. The burner trough is thus cleaned. "Major cleaning" lasts
until the flame temperature has cooled to below 100 °C. The
combustion process automatically restarts.
BURNOUT
The combustion process is ended. After burnout, the
pellet fireplace is in "Off" mode. The "ON/OFF button" must
be pressed to resume heating operation. If timer times are
set, then the pellet fireplace goes to ready. This requires
the pellet fireplace to have been started or put into ready
mode with the on button for the first time.
"MENU" display
08:17
Abb. 3.16 Touch-Bedienfeld - Anzeige MENÜ
Operating keys in the "MENU" display
WI-FI
Selection options: WI-FI ON/OFF;
WI-FI settings; app settings
GENERAL INFORMATION
Software version;
Maintenance interval; Operating hours;
External requirements
GENERAL SETTINGS
Convection air blower; Frost protection;
Night time reduction; Max. output; Temperature drop;
Temperature OFF; Follow-up; Other settings (operating
modes, language settings, timer programs, date/time)
56
25
Desired °C
Ready
Party
"SETTINGS" display
convection
frost protection
night set
max. power
Fig. 3.17
Touch control panel – General settings
08:00
convection
frost protection
night set
max. power
ESC
Fig. 3.18
Touch control panel – Adjust value with arrow buttons
General settings:
By tapping the input field on the right, the control panel appears
below. The value can be adjusted using the arrow buttons, and then
confirmed with OK. The process can be cancelled with ESC.
Frost protection
The frost protection function is activated when the current room
temperature drops below the frost protection temperature which
is set. The combustion process automatically starts for min. 30
minutes. This also occurs in the "Off" operating state (master switch
must be switched on). As soon as the current room temperature
climbs above the frost protection temperature which is set, the
combustion process is ended again and the system switches back
to the previously selected operating mode. The frost protection
temperature can be set to between 5 °C and 10 °C or "---". Factory
setting: ---
VESTA 6 kW
n.c.
5
n.c.
7 °C
5
OK