Télécharger Imprimer la page

Olsberg VESTA 6 KW Instructions De Montage page 47

Publicité

Les langues disponibles

Les langues disponibles

Installation instructions
EN
for the specialist company
Fig. 2.17
Install the lower back wall
● Route the cable such that the cables are not touching any hot
stove surfaces!
● Take care to ensure that no cables are lying next to the motor
slewing ring after installation of the combustion air damper and
no cables can be damaged as a result!
● Activate the combustion air damper and check it is functioning
properly!
● Install the lower back wall again.!
Activating the combustion air damper
The combustion air damper must be activated in the service level
on the touch control panel (see chap. 3.7).
● Switch to the service level via the "Information" menu selection
(for the specialist company only)!
● Enter the password in the service level!
Note: The specialist dealer obtains the password for the service
menu from Olsberg customer service.
● Switch to the "Components" menu!
● Select the "Air flap", switch to "With" and confirm.
● Switch the combustion air damper on and off in the "Relay test"
menu in order to check it is functioning properly!
17:17
enter code
0
Fig. 2.18
Enter the password in the service level
We reserve the right to make technical changes
9x
3
0 0 0
next
17:11
convection
supply air
grate
Fig. 2.19
Activate and verify the combustion air damper ("air flap")
17:11
relay
convection
Supply air
grate
.
Fig. 2.20
Functional test in the Relay test menu
Adjusting the pellet fireplace with the height-adjustable feet
● Adjust the pellet fireplace in the place of installation with the
help of the height-adjustable feet before you connect the pellet
fireplace!
● Unscrew the adjusting feet by approx. 10 mm before installation
in order to minimise sound transmission!
Fig. 2.21
Adjust the pellet fireplace with the adjusting feet
VESTA 6 kW
no
no
no
save
no
no
no
save
47

Publicité

loading