Installation instructions
EN
for the specialist company
● If other accessories are installed in addition to the automatic, mo-
tor-driven combustion air damper, take care to ensure, for reasons
of accessibility, that the combustion air damper is installed first.
For the same reason, the side walls should also be installed first
after installing the combustion air damper!
● Connect the combustion air damper connector into the wiring
harness and to the main circuit board of the pellet fireplace as fol-
lows before installing the combustion air damper:
a) Plug the "19" connector into position "SS4Supply air" on the
main circuit board (see connection diagram!)
b) Plug the "S5" connector into position "SS17_2 Reserve" on the
main circuit board.
c) Plug the "L continuous" connector into the "L continuous" con-
nector in the pellet fireplace wiring harness!
Follow a similar procedure to that which is set out in the "Conversion
of combustion air nozzles for connection from the bottom" chapter:
● Remove the lower back wall!
● Release the hose clamp on the combustion air line!
● Remove the combustion air nozzles!
● Plug the connecting piece for the combustion air damper into the
combustion air line and tighten the hose clamp again!
● Screw the combustion air damper onto the rear or bottom of the
pellet fireplace!
Fig. 2.14
Remove the lower back wall
46
8
Fig. 2.15
Unscrew the combustion air nozzles
3
9x
Fig. 2.16
Install the lower back wall and panel supplied
3
3