Télécharger Imprimer la page

Olsberg VESTA 6 KW Instructions De Montage page 50

Publicité

Les langues disponibles

Les langues disponibles

Operating manual
EN
for the user
3 Operating manual (for the user)
3.1 Commissioning (requirements/preparation)
● Please ensure that no objects made from flammable materials are
located or placed in the radiation range of the fireplace
(See 2.6)!
● Convection air openings may not be covered!
● The precautions for the combustion air supply may not be modi-
fied. In particular, care must be taken to ensure that the necessary
combustion air lines are open during operation of the fireplace!
● Conduct a visual inspection of the burner trough before every
start and clean the burner trough if necessary!
Fig. 3.1
Keep the convection air openings clear
Fig. 3.2
Burner trough visual inspection
50
3.2 Filling with pellets
● Open the cover of the pellet reservoir!
● Fill the pellet reservoir with pellets! Use only pellets which comply
with DIN EN 14961-2 and the DIN-plus certification programme or
the Austrian standard M 7135!
● When pouring in the pellets, take care to ensure that the sawdust
which may be present is not poured into the pellet reservoir!
max. 6 mm
DIN EN 14961-2 / Zerti zierungsprogramm DIN-plus / Ö-Norm M 7135
Fig. 3.3
Only fill the pellet reservoir with permissible pellets
2,1 kW
(1)
ca. 40 h
20 kg
6,0 kW
(5)
ca. 14 h
Fig. 3.4
Filling with pellets / max./min. pellet consumption
max. 30 mm
max. 10 %
ca. 20 kg